This work aimed to assess the biomechanics, using the finite element method (FEM), of traditional titanium Morse taper (MT) dental implants compared to one-piece implants composed of zirconia, polyetheretherketone (PEEK), carbon fiber-reinforced PEEK (CFR-PEEK), or glass fiber-reinforced PEEK (GFR-PEEK). MT and one-piece dental implants were modeled within a mandibular bone section and loaded on an oblique force using FEM. A MT implant system involving a Ti6Al4V abutment and a cp-Ti grade IV implant was compared to one-piece implants composed of cp-Ti grade IV, zirconia (3Y-TZP), PEEK, CFR-PEEK, or GFR-PEEK. Stress on bone and implants was computed and analyzed while bone remodeling prediction was evaluated considering equivalent strain. In comparison to one-piece implants, the traditional MT implant revealed higher stress peak (112 MPa). The maximum stresses on the one-piece implants reached ~80 MPa, regardless their chemical composition. MT implant induced lower bone stimulus, although excessive bone strain was recorded for PEEK implants. Balanced strain levels were noticed for reinforced PEEK implants of which CFR-PEEK one-piece implants showed proper biomechanical behavior. Balanced strain levels might induce bone remodeling at the peri-implant region while maintaining low risks of mechanical failures. However, the strength of the PEEK-based composite materials is still low for long-term clinical performance.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.34890DOI Listing

Publication Analysis

Top Keywords

one-piece implants
20
dental implants
12
implants composed
12
peek cfr-peek
12
bone remodeling
12
implants
11
one-piece dental
8
cfr-peek gfr-peek
8
remodeling prediction
8
finite element
8

Similar Publications

Purpose: This study aimed to evaluate the effect of functional loading on microgaps and microleakage at implant-abutment interfaces (IAIs) in the aesthetic zone when using different abutments and to provide a clinical reference for abutment selection.

Methods: This study included 30 patients with 36 implants divided into three groups: zirconia (Zr)-one-piece custom abutment, titanium (Ti)-custom abutment, and Ti-original abutment. Scanning electron microscopy was used to examine alterations in the microgaps at the IAIs under functional loading.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the long-term outcomes of one-piece narrow-diameter implants (NDIs) and identify factors influencing marginal bone loss (MBL) around them.
  • The analysis involved 25 patients and 40 NDIs over an average of 10.5 years, with a high survival rate of 95.1% for implants and a mean MBL of 0.44 mm, primarily linked to the use of guided bone regeneration (GBR).
  • The findings suggest that NDIs perform well clinically over time, showing acceptable MBL, but further research with larger samples is recommended to confirm these results.
View Article and Find Full Text PDF

Objective: To assess the clinical, radiographic and patient-reported outcome measures, and the success of screw-retained one-piece monolithic zirconia implant-supported restorations in the posterior region during a 1-year follow-up.

Methods: In a prospective case series, 50 single molar sites in the posterior region of 41 patients with a minimum age of 18 years and sufficient bone volume for placing an implant (≥ 8 mm) and space for an anatomical restoration were included. Following prosthetic-driven digital three-dimensional treatment planning, a tissue-level implant with an internal connection was inserted during a one-stage surgical procedure.

View Article and Find Full Text PDF

The Verified Intraoral Scanning Workflow for the Full Arch Implant Patient.

Oral Maxillofac Surg Clin North Am

December 2024

Private Practice of Prosthodontics at Sheets, Paquette & Wu Dental Practice, 360 San Miguel Drive Suite #204, Newport Beach, CA 92660, USA.

The authors have questioned the accuracy of intraoral scanning when restoring the full arch implant patient. Yet clinicians use intraoral scanning (IOS) for this purpose due to the many efficiencies that the IOS workflow offers. This article describes a workflow that is used to enhance the accuracy of the intraoral scan without the need to use photogrammetry.

View Article and Find Full Text PDF

Ascending aortic replacement is a basic procedure in aortic surgery. The crucial factor is the anastomosis method, including the anastomosis site formation. The anastomosis method is usually completely different between true aneurysms and acute aortic dissection because of the difference in the fragility of the aorta.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!