Background: Recently, continuous nonoxygenated hypothermic machine perfusion (HMP) has been implemented as standard preservation method for deceased donor kidneys in the Netherlands. This study was designed to assess the effect of the implementation of HMP on early outcomes after transplantation.

Methods: Kidneys donated in the Netherlands in 2016 and 2017 were intended to be preserved by HMP. A historical cohort (2010-2014) preserved by static cold storage was chosen as the control group. Primary outcome was delayed graft function (DGF). Additional analyses were performed on safety, graft function, and survival up until 2 y after transplantation.

Results: Data were collected on 2493 kidneys. Analyses showed significantly more donation after circulatory death, preemptive transplantation, and retransplants in the project cohort. Of the 681 kidneys that were transplanted during the project, 81% were preserved by HMP. No kidneys were discarded due to HMP-related complications. DGF occurred in 38.2% of the project cohort versus 43.7% of the historical cohort (P < 0.001), with a significantly shorter duration within the project cohort (7 versus 9 d, P = 0.003). Multivariate regression analysis showed an odds ratio of 0.69 (95% confidence interval, 0.553-0.855) for the risk of DGF when using HMP compared with cold storage (P = 0.001). There was no significant difference in kidney function, graft survival, and recipient survival up until 2 y posttransplantation.

Conclusions: This study showed that HMP as a standard preservation method for deceased donor kidneys is safe and feasible. HMP was associated with a significant reduction of DGF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9038234PMC
http://dx.doi.org/10.1097/TP.0000000000003845DOI Listing

Publication Analysis

Top Keywords

hypothermic machine
8
machine perfusion
8
standard preservation
8
preservation method
8
method deceased
8
deceased donor
8
donor kidneys
8
preserved hmp
8
historical cohort
8
graft function
8

Similar Publications

Hypothermic oxygenated machine perfusion (HOPE) has emerged as a critical innovation in liver transplantation (LTx), offering significant protection against ischemia-reperfusion injury (IRI). This study focuses on quantifying and characterizing immune cells flushed out during HOPE to explore its effects on graft function and post-transplant outcomes. Fifty liver grafts underwent end-ischemic HOPE.

View Article and Find Full Text PDF

Hypothermic oxygenated machine perfusion (HOPE) preconditions liver grafts before transplantation. While beneficial effects on patient outcomes were demonstrated, biomarkers for viability assessment during HOPE are scarce and lack validation. This study aims to validate the predictive potential of perfusate flavin mononucleotide (FMN) during HOPE to enable the implementation of FMN-based assessment into clinical routine and to identify safe organ acceptance thresholds.

View Article and Find Full Text PDF

Chronic kidney disease (CKD) is a prevalent disease affecting almost 10% of the world's population, with many cases progressing to end-stage kidney disease (ESKD). Kidney transplantation (KT) is the gold-standard treatment for ESKD. Due to growing KT waitlists, the deceased kidney donor (DKDs) criteria have expanded to increase the number of available kidney grafts.

View Article and Find Full Text PDF

Maintaining an animal's body temperature during magnetic resonance imaging (MRI) poses great challenges, as many temperature measuring devices and warming systems are incompatible with the MRI machine. The aim of this study was to examine body temperature changes and evaluate the impact of using a hot water bottle and a cloth blanket on rectal temperature during magnetic resonance imaging in cats. We included in this study 30 cats from different breeds that underwent magnetic resonance imaging for 60 min that were randomly divided into a passively insulated group (G1) covered with a blanket ( = 15) and a positively heated group (G2) using a silicone hot water bottle under the abdomen and the same cloth blanket over the cat ( = 15).

View Article and Find Full Text PDF

Xenotransplantation (XTx) is an increasingly realistic solution to the organ shortage. Clinical XTx may require off-site procurement in a designated pathogen free (DPF) facility necessitating a period of cold ischemic time during transportation. This study evaluates the impact of different kidney preservation strategies on early graft function in pig-to-baboon XTx in a series of eight cases of pig-to-baboon xenotransplantation performed after five hours of cold ischemic time and compares these results to six cases of pig-to-baboon xenotransplantation performed with minimal ischemic time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!