A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility of using an intraoral scanner for a complete arch digital scan, part 2: A comparison of scan strategies. | LitMetric

Feasibility of using an intraoral scanner for a complete arch digital scan, part 2: A comparison of scan strategies.

J Prosthet Dent

Professor, Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea. Electronic address:

Published: February 2023

Statement Of Problem: Various strategies for intraoral scanners (IOSs) can be used to scan the oral cavity. However, research on the scan range that can be clinically is lacking.

Purpose: The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of complete arch scans as part of the scan strategy and analyze the clinically recommended scan range.

Material And Methods: A computer-aided design (CAD) reference model was obtained with an industrial scanner. A CAD test model was obtained by using 6 IOSs (TRIOS2, TRIOS3, CS3500, CS3600, i500, and Primescan) to apply 2 scan strategies and 2 dental laboratory scanners (DOF and E1) (N=15). All the teeth were segmented in the reference model by using 3D inspection software (Geomagic control X). The 3D analysis was performed by aligning the test model to the reference model and evaluating the root mean square values of all segmented teeth. The Mann-Whitney U-test was performed for a statistical comparison of the 2 scan strategies (α=.05), the Kruskal-Wallis test (α=.05) was used to compare the scanners, and the Mann-Whitney U-test and Bonferroni correction method were used as post hoc tests (α=.0017).

Results: The 8 scanners obtained significant differences in the root mean square values of all teeth (P<.001). The root mean square value of IOSs increased from the left maxillary second molar to the right maxillary second molar. The difference in the 2 scan strategies showed different patterns depending on the IOS.

Conclusions: Scan strategy 2 improved the accuracy of the IOSs. TRIOS2 and CS3500 are for single crowns; TRIOS3, CS3600, and i500 are for short-span prostheses; and Primescan is for long-span prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2021.05.021DOI Listing

Publication Analysis

Top Keywords

scan strategies
12
reference model
12
complete arch
8
scan
8
comparison scan
8
test model
8
root square
8
square values
8
mann-whitney u-test
8
model
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!