Electrospray Ionization Inside the Ion Inlet Tube: Multijet Mode Operation.

J Am Soc Mass Spectrom

Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.

Published: July 2021

We investigated the electrospray ionization inside the narrow channel of the ion inlet tube. An insulating emitter capillary made of fused silica with a 0.2 mm outer diameter was inserted into the ion inlet tubes with a 0.5 and 0.6 mm inner diameter to aspirate all the charged droplets. A custom-made ion inlet tube with two side holes near its entrance is used to observe the spraying condition. The spray current is measured and monitored during the MS acquisition using isolation amplifiers. Because the emitter is cylindrically surrounded in close proximity by the metallic inner wall, it is difficult to obtain a stable and symmetric Taylor cone with its apex at the center of the emitter. Instead, a stable operation under a flow rate of 1-4 μL/min is found to be in the form of a multicone-jet mode with two or more Taylor cones anchoring around the rim of the emitter. The emitted charged droplet jets are dragged from hitting the wall by the fast-flowing air inside the inlet tube. Comparison with the typical cone-jet and multijet mode operated several millimeters outside the inlet capillary shows signal enhancements for protein standards.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jasms.1c00157DOI Listing

Publication Analysis

Top Keywords

ion inlet
16
inlet tube
16
electrospray ionization
8
ionization inside
8
multijet mode
8
inlet
6
ion
4
inside ion
4
tube
4
tube multijet
4

Similar Publications

Recovery of wastewater from the pulp and paper industry by cellulose acetate reverse osmosis membrane.

Int J Biol Macromol

January 2025

Key Laboratory of Pulp and Paper Science and Technology of Shandong Province, Ministry of Education, State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, Shandong, China.

The high salt content and color are regarded as a major challenge to the reuse of industrial wastewater. In the present study, the application of cellulose acetate reverse osmosis (RO) membrane in combination with microfiltration (MF), ultrafiltration (UF), or nanofiltration (NF) process was investigated in the purification of biological and Fenton treated pulp and paper wastewater. In the first step, the effect of pH and inlet pressures on the membrane fouling was investigated.

View Article and Find Full Text PDF

Stylus pen-based ambient ionization mass spectrometry for the analysis of volatiles and semivolatiles from liquid, viscous, and solid samples.

Anal Chim Acta

February 2025

Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan; International College of Semiconductor Technology, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan. Electronic address:

Background: Ambient ionization mass spectrometry (MS) has attracted significant attention due to its simplicity and ease of operation. Contactless, or field-induced, ionization is one of the ambient ionization techniques. In this approach, no direct electrical contact or additional voltage is required on the ionization-assisted substrate.

View Article and Find Full Text PDF

Enhancing Tribo-Rehydration in Hydrogel by Brush-Like Surface and Its Modulation.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China.

Synovial exudation, creeping, and lubrication failure in natural cartilage under a long-term normal loading can be counteracted by a tribo-rehydration (sliding-induced rehydration) phenomenon. Hydrogels, as porous materials, can also restore interfacial lubrication and overcome creep through this strategy. At appropriate sliding velocities, water molecules at the interface contact inlet are driven by hydrodynamic pressures into the porous network to resist creep extrusion.

View Article and Find Full Text PDF

Phased structures for lossless ion manipulation offer significant improvements over the scanning second gate method for coupling with ion trap mass analyzers. With an experimental run time of under 1 min for select conditions and an average run time of less than 4 min, this approach significantly reduces experimental time while enhancing the temporal duty cycle. The outlined SLIM system connects to an ion trap mass analyzer via a PCB stacked ring ion guide, which replaces the commercial ion optics and capillary inlet.

View Article and Find Full Text PDF

Fluorescent lifetimes of dissolved organic matter (DOM) and associated physicochemical parameters were measured over 14 months in an estuary in Southern California, USA. Measurements were made on 77 samples from sites near the inlet, mid-estuary, and outlet to maximize the range of physicochemical variables. Time-resolved fluorescence data were well fit to a triexponential model with an intermediate lifetime component (τ: 1 to 5 ns), a long lifetime component (τ: 2 to 15 ns), and a short lifetime component (τ: < 1 ns).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!