A Cavopulmonary Assist Device for Long-Term Therapy of Fontan Patients.

Semin Thorac Cardiovasc Surg

Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany; Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria. Electronic address:

Published: April 2022

Treatment of univentricular hearts remains restricted to palliative surgical corrections (Fontan pathway). The established Fontan circulation lacks a subpulmonary pressure source and is commonly accompanied by progressively declining hemodynamics. A novel cavopulmonary assist device (CPAD) may hold the potential for improved therapeutic management of Fontan patients by chronic restoration of biventricular equivalency. This study aimed at translating clinical objectives toward a functional CPAD with preclinical proof regarding hydraulic performance, hemocompatibility and electric power consumption. A prototype composed of hemocompatible titanium components, ceramic bearings, electric motors, and corresponding drive unit was manufactured for preclinical benchtop analysis: hydraulic performance in general and hemocompatibility characteristics in particular were analyzed in-silico (computational fluid dynamics) and validated in-vitro. The CPAD's power consumption was recorded across the entire operational range. The CPAD delivered pressure step-ups across a comprehensive operational range (0-10 L/min, 0-50 mm Hg) with electric power consumption below 1.5 W within the main operating range. In-vitro hemolysis experiments (N = 3) indicated a normalized index of hemolysis of 3.8 ± 1.6 mg/100 L during design point operation (2500 rpm, 4 L/min). Preclinical investigations revealed the CPAD's potential for low traumatic and thrombogenic support of a heterogeneous Fontan population (pediatric and adult) with potentially accompanying secondary disorders (e.g., elevated pulmonary vascular resistance or systemic ventricular insufficiency) at distinct physical activities. The low power consumption implied adequate settings for a small, fully implantable system with transcutaneous energy transfer. The successful preclinical proof provides the rationale for acute and chronic in-vivo trials aiming at the confirmation of laboratory findings and verification of hemodynamic benefit.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.semtcvs.2021.06.016DOI Listing

Publication Analysis

Top Keywords

power consumption
16
cavopulmonary assist
8
assist device
8
fontan patients
8
preclinical proof
8
hydraulic performance
8
electric power
8
operational range
8
fontan
5
device long-term
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!