Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To define and evaluate hemodynamic criteria to distinguish between classical orthostatic hypotension (cOH) and vasovagal syncope (VVS) in tilt table testing (TTT).
Methods: Inclusion criteria for VVS were a history of VVS and tilt-induced syncope defined as a blood pressure (BP) decrease and electroencephalographic changes during syncope with complaint recognition. Criteria for cOH were a history of cOH and a BP decrease meeting published criteria. Clinical diagnoses were established prior to TTT. We assessed (1) whether the decrease of systolic BP accelerated, "convex," or decelerated, "concave"; (2) the time from head-up tilt to when BP reached one-half its maximal decrease; (3) the difference between baseline heart rate (HR) and HR at BP nadir. We calculated the diagnostic yield of optimized thresholds of these features and their combinations.
Results: We included 82 VVS cases (40% men, median age 44 years) and 65 cOH cases (66% men, median age 70 years). BP decrease was concave in cOH in 79% and convex in VVS in 94% (p < 0.001). The time to reach half the BP decrease was shorter in cOH (median 34 sec, interquartile range (IQR) 19-98 sec) than in VVS (median 1571 sec, IQR 1381-1775 sec, p < 0.001). Mean HR increased by 11 ± 11 bpm in cOH and decreased by 20 ± 19 bpm in VVS (p < 0.001). When all three features pointed to VVS, sensitivity for VVS was 82% and specificity was 100%. When all three pointed to cOH, sensitivity for cOH was 71% and specificity was 100%.
Interpretation: These new hemodynamic criteria reliably differentiate cOH from VVS.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8351382 | PMC |
http://dx.doi.org/10.1002/acn3.51412 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!