Background: A major perspective for the use of circulating tumor DNA (ctDNA) in the clinical setting of non-small cell lung cancer (NSCLC) is expected as predictive factor for resistance and response to EGFR TKI therapy and, especially, as a non-invasive alternative to tissue biopsy. However, ctDNA is both highly fragmented and mostly low concentrated in plasma and serum. On this basis, it is important to use a platform characterized by high sensitivity and linear performance in the low concentration range. This motivated us to evaluate the newly developed and commercially available SensiScreen® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods. The validation was made in three independent European laboratories using two cohorts on a total of 68 unique liquid biopsies.

Results: Using artificial samples containing 1600 copies of WT DNA spiked with 50% - 0.1% of mutant copies across a seven-log dilution scale, we assessed the sensitivity, linearity, repeatability and accuracy for the p.T790M, p.L858R and exon 19 deletion assays of the SensiScreen® EGFR Liquid assay platform. The lowest value detectable ranged from 0.5% to 0.1% with R2≥0,97 indicating good linearity. High PCR efficiency was shown for all three assays. In 102 single PCRs each containing theoretical one copy of the mutant at initiating, assays showed repeatable positivity in 75.5% - 80.4% of reactions. At low ctDNA levels, as in plasma, the SensiScreen® EGFR Liquid assay platform showed better sensitivity than the Therascreen® EGFR platform (Qiagen) and equal performance to the ctEGFR Mutation Detection Kit (EntroGen) and the IOT® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) with 100% concordance at the sequence level.

Conclusion: For profiling clinical plasma samples, characterized by low ctDNA abundance, the SensiScreen® EGFR Liquid assay is able to identify down to 1 copy of mutant alleles and with its high sensitivity, linearity and accuracy it may be a competitive platform of choice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8224962PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0253687PLOS

Publication Analysis

Top Keywords

sensiscreen® egfr
16
egfr liquid
16
liquid assay
16
assay platform
12
sensitivity linearity
12
high sensitivity
8
linearity repeatability
8
repeatability accuracy
8
copy mutant
8
low ctdna
8

Similar Publications

Successful treatment of epidermal growth factor receptor exon 19 deletion non-small cell lung cancer with almonertinib after osimertinib-induced interstitial lung disease: A case report.

J Cancer Res Ther

December 2024

Department of Oncology, The First Affiliated Hospital of Shandong First Medical University and Shandong Provincial Qianfoshan Hospital, Shandong Lung Cancer Institute, Shandong, China.

Osimertinib, a third-generation epidermal growth factor receptor (EGFR)-tyrosine kinase inhibitor (TKI), has revolutionized one of the standard most efficient treatments for EGFR mutation-positive non-small cell lung cancer (NSCLC). Osimertinib, a third-generation EGFR-TKI, is currently one of most efficient treatments in clinical practice. However, it has a potentially fatal side effect: interstitial lung disease (ILD).

View Article and Find Full Text PDF

GraphkmerDTA: integrating local sequence patterns and topological information for drug-target binding affinity prediction and applications in multi-target anti-Alzheimer's drug discovery.

Mol Divers

January 2025

Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases Ministry of Education, Jiangxi Province Key Laboratory of Biomaterials and Biofabrication for Tissue Engineering, Gannan Medical University, Ganzhou, 341000, Jiangxi, China.

Identifying drug-target binding affinity (DTA) plays a critical role in early-stage drug discovery. Despite the availability of various existing methods, there are still two limitations. Firstly, sequence-based methods often extract features from fixed length protein sequences, requiring truncation or padding, which can result in information loss or the introduction of unwanted noise.

View Article and Find Full Text PDF

Background: The estimation of glomerular filtration rate (eGFR) is essential in the early detection of diabetic nephropathy. We herein compare the performance of common eGFR formulas against a gold standard measurement of GFR in patients with diabetes mellitus.

Methods: GFR was measured in 93 patients with diabetes mellitus using iohexol clearance as the reference standard.

View Article and Find Full Text PDF

Epidermal growth factor receptor (EGFR)-tyrosine kinase inhibitors (TKIs) effectively treat EGFR-mutant lung adenocarcinoma, demonstrating initial efficacy but eventually leading to acquired resistance. Small cell transformation is a rare resistance mechanism to EGFR-TKIs in lung adenocarcinoma, which can complicate clinical diagnosis and treatment. We present a patient with lung adenocarcinoma who underwent a prior pneumonectomy and adjuvant chemotherapy and was treated with osimertinib after the recurrence of lung cancer.

View Article and Find Full Text PDF

Tumor-derived extracellular vesicle (tEV)-associated RNAs hold promise as diagnostic biomarkers, but their clinical use is hindered by the rarity of tEVs among nontumor EVs. Here, we present EV-CLIP, a highly sensitive droplet-based digital method for profiling EV RNA. EV-CLIP utilizes the fusion of EVs with charged liposomes (CLIPs) in a microfluidic chip.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!