Background: Femoral torsion imaging measurements and classifications are heterogeneous throughout the literature, and the influence of femoral torsion on clinically meaningful outcome improvement after hip arthroscopy for femoroacetabular impingement syndrome (FAIS) has not been well studied.

Purpose: To (1) perform a computed tomography (CT)-based analysis to quantify femoral torsion in patients with FAIS and (2) explore the relationship between the orientation and magnitude of femoral torsion and the propensity for clinically meaningful outcome improvement after hip arthroscopy.

Study Design: Cohort study; Level of evidence, 3.

Methods: Consecutive patients who underwent hip arthroscopy for FAIS between January 2012 and April 2018 were identified. Inclusion criteria were the presence of preoperative CT imaging with transcondylar slices of the knee and minimum 2-year outcome measures. Exclusion criteria were revision hip arthroscopy, Tönnis grade >1, congenital hip condition, hip dysplasia (lateral center-edge angle <20°), and concomitant gluteus medius or minimus repair. Torsion groups were defined as severe retrotorsion (SR; <0°), moderate retrotorsion (MR; 0°-5°), normal torsion (N; 5°-20°), moderate antetorsion (MA; 20°-25°), and severe antetorsion of antetorsion (SA; >25°). Treatment did not differ based on femoral torsion. Patient characteristics and clinical outcomes were analyzed, including the Hip Outcome Score-Activities of Daily Living (HOS-ADL), Hip Outcome Score-Sports Subscale (HOS-SS), modified Harris Hip Score (mHHS), international Hip Outcome Tool (iHOT-12), visual analog scale (VAS) for pain, and VAS for satisfaction. Achievement of the minimal clinically important difference (MCID) and patient acceptable symptom state (PASS) by torsion stratification was analyzed using the chi-square test. Inter- and intrarater reliabilities for CT measurements were 0.980 ( < .001) and 0.974 ( < .001), respectively.

Results: The study included 573 patients with a mean ± SD age and body mass index of 32.6 ± 11.8 years and 25.6 ± 10.6, respectively. The mean ± SD femoral torsion for the study population was 12.3°± 9.3°. After stratification, the number of patients within each group and the mean ± SD torsion for each group were as follows: SR (n = 36; -6.5°± 7.1°), MR (n = 80; 2.8°± 1.4°), N (n = 346; 12.3°± 4.1°), MA (n = 64; 22.2°± 1.4°), and SA (n = 47; 30.3°± 3.7°). No significant differences in age, body mass index, sex, tobacco use, workers' compensation status, or participation in physical activity were observed at baseline. No significant differences were seen in pre- and postoperative VAS pain, mHHS, HOS-ADL, HOS-SS, iHOT-12, or postoperative VAS satisfaction among the cohorts. Furthermore, no statistically significant differences were found in the proportion of patients who achieved the MCID or the PASS for any outcome among the groups.

Conclusion: The orientation and severity of femoral torsion at the time of hip arthroscopy for FAIS did not influence the propensity for clinically significant outcome improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1177/03635465211021610DOI Listing

Publication Analysis

Top Keywords

femoral torsion
20
hip arthroscopy
16
clinically meaningful
12
improvement hip
12
orientation magnitude
8
magnitude femoral
8
torsion propensity
8
propensity clinically
8
arthroscopy femoroacetabular
8
femoroacetabular impingement
8

Similar Publications

The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Purpose: Malalignment of the lower extremity can affect one, two or all three anatomic planes. We hypothesized an influence between the malalignment of the coronal and axial planes.

Methods: A total of 356 lower extremities of 226 patients were included.

View Article and Find Full Text PDF

Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.

Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.

View Article and Find Full Text PDF

Purpose: To propose a new sign of patellar maltracking in recurrent patellar dislocation (RPD) and compare the differences in lower limb rotational and bony structural abnormalities among the different signs.

Patients And Methods: A retrospective study included 279 patients (mean age: 22 years; female: 81%) who underwent primary surgery for RPD over the past 4 years was performed. The patients were grouped based on the characteristics of patellar tracking: low-, moderate- and high-grade J-sign.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!