Purpose: As the monolateral external fixator is increasingly used in trauma-control and definitive management for high-energy long bone fractures, timing the fixator removal remains a challenge for surgeons. The purpose of this study was to determine the feasibility and effectiveness of the bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo as a guide to removing a monolateral external fixator safely.
Methods: A total of 131 patients with tibial shaft fractures treated by the monolateral external fixator in our institution were collected from January 2013 to July 2019. In group I, the fixators were removed based on the clinical and radiological assessment only by the treating surgeon. As for group II, the axial load-share (LS) ratio test was accomplished by another medical team without the knowledge of the clinical results. The external fixator was removed when the mechanical test outcome (LS ratio < 10%) was consistent with the conclusion drawn from the clinical and radiological assessment (bone union achieved) by the treating surgeon.
Results: There was no statistical significance in demographic data between the two groups (P > 0.05). In group I, four patients suffered refracture (the refracture rate was 7.7%) after fixator removal and were successfully treated by an intramedullary nail. In group II, 71 patients underwent fixator removal after the first mechanical test, and another eight patients terminated the external fixation after the second test. None of the 79 patients in group II suffered refracture (the refracture rate was 0%). There was statistical significance in the refracture rate between the two groups (P < 0.05).
Conclusion: The bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo using the additional circular frame components is an effectively quantitative indicator to complement the clinical assessment of fracture healing in a monolateral external fixation treatment. Removal of the monolateral external fixator is safe when the axial load-share ratio dropped below 10%.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8626363 | PMC |
http://dx.doi.org/10.1007/s00264-021-05116-z | DOI Listing |
Trauma Case Rep
February 2025
Department of Orthopaedic Surgery and Sports Medicine, University at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Buffalo, NY 14203, United States of America.
Introduction: Revision quadriceps tendon repair is a challenging problem. In this four-case series, novel quadriceps tendon revision resulted in improved range of motion and durable repair for patients with recurrent rupture.
Methods: Our technique includes a combination of a running locked #5 FiberWire or 2 mm SutureTape suture placed through parallel medial, lateral, and central drill holes in the patella with running Krackow-type quadriceps tendon repair medially and laterally resulting in four strands, delivering the vastus medialis and medial quadriceps tendon to an anatomic repair at the superior pole of the patella, with 2 sutures passed centrally and 1 each passed medially and laterally and then tied.
Am J Vet Res
January 2025
Objective: This study aimed to evaluate the clinical and radiologic findings in the treatment of live oligotrophic and pseudoarthrosis nonunions in cats using a linear external fixator.
Methods: The study included 10 cats of various breeds, ages, and sexes that had previously undergone osteosynthesis at another clinic but did not achieve successful results. These cats were diagnosed with nonunion based on clinical and radiographic examinations conducted at the Clinic of the Surgery Department, Siirt University Animal Health Practice and Research Hospital between 2022 and 2023.
J Am Podiatr Med Assoc
January 2025
†Jesse Brown VA Medical Center,820 S Damen Ave, Chicago, IL.
Total contact casting is the gold standard for plantar foot ulcers but has been questioned in heel pressure ulcers. Current offloading of heel ulcers is typically removable offloading boots. We describe using a modified posterior splint to offload heel ulcers in nonweightbearing patients.
View Article and Find Full Text PDFAME Case Rep
November 2024
Department of Orthopaedic Surgery, Sugita Genpaku Memorial Obama Municipal Hospital, Fukui, Japan.
Background: Open pelvic fractures are rare but represent a serious clinical problem with high mortality rates. Acute mortality is often associated with hemorrhage, whereas delayed mortality is most often associated with sepsis and multiple organ failure. We report a case of Wang's classification of type II open pelvic ring fracture with hemorrhagic shock and septic shock from gas gangrene.
View Article and Find Full Text PDFInjury
January 2025
Department of Orthopaedic Surgery and Rehabilitation, University of Florida-Jacksonville, Jacksonville, FL USA. Electronic address:
Introduction: External fixators are utilized to temporarily stabilize bicondylar tibial plateau fractures. They can be prepped during definitive surgery to help maintain fracture length and alignment. However, there is a potential for increased infection by leaving the external fixator on during the surgery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!