Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Transit time flow measurement (TTFM) is widely used in coronary artery bypass grafting (CABG); however, its predictive value is unclear. We aimed to identify new factors to evaluate graft quality using fast Fourier transform (FFT).
Methods: Intraoperative and postoperative 2-year follow-up data of 114 patients undergoing CABG from January 2017 to December 2018 were collected. The TTFM waveform was transformed by FFT. Mean graft flow (MGF), pulse index, the amplitude of the main wave in FFT (H), the amplitude of the first harmonic (H), H/H, and the frequency of the first harmonic (P) were analyzed as predictors using logistic regression and receiver operating characteristic (ROC) curves.
Results: The overall graft patency rate was 80.3%, and the incidence of major adverse cardiac and cerebrovascular events (MACCEs) was 14.9%. The results demonstrate that compared with the graft failure group, MGF, H, and H were higher, but H and P were lower in the patent group. With univariate and multivariate logistic regression analyses, the decrease in H and H and the increase in P were independent risk factors for graft failure, while the decrease in MGF and the increase in H/H were only statistically significant with a univariate analysis. In the cardiovascular events group, the increase in P was an independent risk factor. With a ROC curve analysis, MGF, H, H, H/H, and P predicted graft failure, while only P predicted cardiovascular events. None of the indicators showed predictive value for MACCEs.
Conclusions: TTFM waveforms after FFT can be used to evaluate graft quality and cardiovascular events, but have no predictive value for MACCEs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8182493 | PMC |
http://dx.doi.org/10.21037/jtd-21-178 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!