Background: A number of nucleic acid amplification tests (NAATs) for SARS-CoV-2 with different reagents have been approved for clinical use in Japan. These include research kits approved under emergency use authorization through simplified process to stabilize the supply of the reagents. Although these research kits have been increasingly used in clinical practice, limited data is available for the diagnostic performance in clinical settings.
Methods: We compared sensitivity, specificity, and cycle threshold (Ct) values obtained by NAATs using 10 kits approved in Japan including eight kits those receiving emergency use authorization using 69 frozen-stored clinical samples including 23 positive samples with various Ct values and 46 negative samples.
Results: Viral copy number of the frozen-stored samples determined with LightMix E-gene test ranged from 0.6 to 84521.1 copies/μL. While no false-positive results were obtained by any of these tests (specificity: 100% [95% CI, 88.9%-100%]), sensitivity of the nine tests ranged from 68.2% [95% CI, 45.1%-86.1%] to 95.5% [95% CI, 77.2%-99.9%] using LightMix E-gene test as the gold standard. All tests showed positive results for all samples with ≥100 copies/μL. Significant difference of Ct values even among tests amplifying the same genetic region (N1-CDC, N2) was also observed.
Conclusion: Difference in the diagnostic performance was observed among NAATs approved in Japan. Regarding diagnostic kits for emerging infectious diseases, a system is needed to ensure both rapidity of reagent supply and accuracy of diagnosis. Ct values, which are sometimes regarded as a marker of infectivity, are not interchangeable when obtained by different assays.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8221491 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0252757 | PLOS |
Emerg Med J
January 2025
UK Health Security Agency, London, UK.
Background: Rapid identification of individuals with acute respiratory infections is crucial for preventing nosocomial infections. For rapid diagnosis, especially in EDs, lateral flow devices (LFDs) are a convenient, inexpensive option with a rapid turnaround. Several 'multiplex' LFDs (M-LFDs) now exist, testing for multiple pathogens from a single swab sample.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Department of Biomedical Engineering, University of Cincinnati, UC Bioscience Center, 3159 Eden Ave., Cincinnati, Ohio, 45221, UNITED STATES.
Ultrasound echo decorrelation imaging can successfully monitor and control thermal ablation of animal liver and tumor tissue ex vivo and in vivo. However, normal and diseased human liver has substantially different physical properties that affect echo decorrelation. Here, effects of human liver tissue condition on ablation guidance by three-dimensional echo decorrelation imaging are elucidated in experiments testing closed-loop control of radiofrequency ablation (RFA) in normal and diseased human liver tissue ex vivo.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China.
Long-Time Coherent Integration (LTCI) utilizes digital integration to combine multiple coherent cycles, thereby improving the signal-to-noise ratio (SNR). Our previous work introduced single-bit LTCI, an approach optimized for FPGA implementation, but faced challenges of output saturation at high SNR levels and inherent limitations in SNR gain (SNRG), which are insufficient for certain applications. This paper presents a threshold tracking method that improves the performance of single-bit LTCI in high-SNR scenarios.
View Article and Find Full Text PDFJ Med Virol
January 2025
Department of Laboratory Medicine, Ziekenhuis aan de Stroom, Antwerp, Belgium.
Three hospitals implemented molecular point-of-care tests (POCTs) to screen patients for SARS-CoV-2 infection upon admission during the 2021/2022 influenza season, which in Belgium lasted from January to April 2022. The samples were simultaneously tested for influenza A/B. Influenza positivity at admission was examined in relation to patient characteristics and symptomatology.
View Article and Find Full Text PDFMed Sci Sports Exerc
November 2024
Department of Biomedical Sciences for Health, Università degli Studi di Milano, ITALY.
Purpose: Cigarette smoking (CS) induces systemic changes that impair cardiorespiratory and muscular function both at rest and during exercise. Although these abnormalities are reported in sedentary, middle-aged smokers (SM) with pulmonary disease, few and controversial studies focused on young, physically active SM at the early stage of smoking history. This study aimed at assessing the impact CS on cardiorespiratory and metabolic response during an incremental test and the subsequent recovery in young, physically active SM without known lung or cardiovascular disease.