Background: Many studies have reported the predictors of atrial fibrillation (AF) recurrence after persistent AF (peAF) ablation. However, the correlation between the atrial defibrillation threshold (DFT) for internal cardioversion (IC) and AF recurrence rate is unknown. Here we investigated the relationship between the DFT prior to catheter ablation for peAF and AF recurrence.
Hypothesis: DFT prior to ablation was the predictive factor for AF recurrence after peAF ablation.
Methods: From June 2016 to May 2019, we enrolled 82 consecutive patients (mean age, 65.0 ± 12.4 years), including 45 with peAF and 37 with long-standing peAF, at Hamamatsu Medical Center. To assess the DFT, we performed IC with gradually increasing energy prior to radiofrequency application.
Results: Forty-nine and 33 patients showed DFT values less than or equal to 10 J (group A) and greater than 10 J or unsuccessful defibrillation (group B). During the mean follow-up duration of 20.5 ± 13.1 months, patients in group B showed significantly higher AF recurrence rates than those in group A after the ablation procedure (p = .017). Multivariate analysis revealed that DFT was the only predictive factor for AF recurrence (odds ratio, 1.07; 95% CI, 1.00-1.13, p = .047).
Conclusions: The DFT for IC was among the strongest prognostic factors in the peAF ablation procedure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8364735 | PMC |
http://dx.doi.org/10.1002/clc.23679 | DOI Listing |
J Magn Reson Imaging
December 2024
Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Background: In arrhythmogenic cardiomyopathy (ACM), left ventricle-dominant presentation has poorer outcomes than right-dominant presentation, suggesting that interventricular functional disparity might play a role in patients' prognosis. However, the prognostic impact of ventricular functional discordance in ACM patients remains unknown.
Purpose: To assess whether ventricular functional disparity measured as ventricular discordance index, defined as the ratio of right-ventricular ejection fraction (RVEF) to left-ventricular ejection fraction (LVEF), might reveal prognostic disparities between phenotypes and offer added risk stratification value.
Pacing Clin Electrophysiol
January 2025
Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany.
Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.
Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.
Results: The majority of patients (87.
Circ Arrhythm Electrophysiol
December 2024
Heart and Lung Center (P.P., J.L., D.V., H.M., P.S., H.-K.N., M.K.).
Background: Cardiac sarcoidosis involves a significant but difficult-to-define risk of sudden cardiac death (SCD). Current guidelines recommend consideration of an implantable cardioverter defibrillator for patients with extensive or significant myocardial late gadolinium enhancement (LGE) on cardiac magnetic resonance imaging. However, extensive/significant LGE is not defined.
View Article and Find Full Text PDFJ Cardiol Cases
December 2024
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Unlabelled: New cardiac implantable electronic devices (CIEDs), such as leadless pacemakers and subcutaneous implantable cardioverter defibrillators (S-ICDs), are being used in patients with adult congenital heart disease. The selection of CIEDs often requires careful consideration due to technical challenges posed by a unique heart structure. A 27-year-old man following a surgical tetralogy of Fallot (TOF) repair developed non-sustained ventricular tachycardia, sick sinus syndrome, and complete atrioventricular block.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!