A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The evolution of long-term pediatric ventricular assistance devices: a critical review. | LitMetric

The evolution of long-term pediatric ventricular assistance devices: a critical review.

Expert Rev Med Devices

Arts Et Metiers Institute of Technology, CNAM, LIFSE, HESAM University, Paris, France.

Published: August 2021

: The gap between the number of heart failure patients and the number of potential heart donors has never been larger than today, especially among the pediatric population. The use of mechanical circulatory support is seen as a potential alternative for clinicians to treat more patients. This treatment has proven its efficiency on short-term use. However, in order to replace heart transplant, the techniques should be used over longer periods of time.: This review aims at furnishing an engineering vision of the evolution of ventricular assistance devices used in pediatrics. A critical analysis of the clinical complications related to devices generation is made to give an overview of the design improvements made since their inception.: The long-term use of a foreign device in the body is not without consequences, especially among fragile pediatric patients. Moreover, the size of their body parts increases the technical difficulties of such procedure. The balance between the living cells of the body is disturbed by the devices, mostly by the shear stress generated. To provide a safe mechanical circulatory support for long-term use, the devices should be more hemocompatible, preserving blood cells, adapted to the patient's systemic grid and miniaturized for pediatric use.

Download full-text PDF

Source
http://dx.doi.org/10.1080/17434440.2021.1947245DOI Listing

Publication Analysis

Top Keywords

ventricular assistance
8
assistance devices
8
mechanical circulatory
8
circulatory support
8
devices
5
evolution long-term
4
pediatric
4
long-term pediatric
4
pediatric ventricular
4
devices critical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!