Aims: The anaerobic threshold (AT) is an important cardiopulmonary exercise test (CPET) parameter both in healthy and in patients. It is normally determined with three approaches: V-slope method, ventilatory equivalent method, and end-tidal method. The finding of different AT values with these methods is only anecdotic. We defined the presence of a double threshold (DT) when a ΔVO2 > 15 mL/min was observed between the V-slope method (met AT) and the other two methods (vent AT). The aim was to identify whether there is a DT in healthy subjects.

Methods And Results: We retrospectively analysed 476 healthy subjects who performed CPET in our laboratory between 2009 and 2018. We identified 51 subjects with a DT (11% of cases). Cardiopulmonary exercise test data at rest and during the exercise were not different in subjects with DT compared to those without. Met AT always preceded vent AT. Compared to subjects without DT, those with DT showed at met AT lower carbon dioxide output (VCO2), end-tidal carbon dioxide tension (PetCO2) and respiratory exchange ratio (RER), and higher ventilatory equivalent for carbon dioxide (VE/VCO2). Compared to met AT, vent AT showed a higher oxygen uptake (VO2), VCO2, ventilation, respiratory rate, RER, work rate, and PetCO2 but a lower VE/VCO2 and end-tidal oxygen tension. Finally, subjects with DT showed a higher VO2 increase during the isocapnic buffering period.

Conclusion: Double threshold was present in healthy subjects. The presence of DT does not influence peak exercise performance, but it is associated with a delayed before acidosis-induced hyperventilation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurjpc/zwab100DOI Listing

Publication Analysis

Top Keywords

healthy subjects
12
carbon dioxide
12
anaerobic threshold
8
threshold healthy
8
cardiopulmonary exercise
8
exercise test
8
v-slope method
8
ventilatory equivalent
8
double threshold
8
compared met
8

Similar Publications

Purpose: To assess physiological metrics during the use of a commercially available bilateral active ankle exoskeleton during a challenging military-relevant task and if use of the exoskeleton during this task influences: metabolic load, physiological measures or rate of perceived exertion.

Methods: Nine healthy volunteers (5M, 4F) completed this randomized cross-over design trial, with a baseline visit and two randomized test sessions (with/without the exoskeleton). Variables included impact on time to exhaustion during walking on a treadmill at varying speeds and gradients (0-15%) at 26.

View Article and Find Full Text PDF

Biofield Therapies Clinical Research Landscape: A Scoping Review and Interactive Evidence Map.

J Integr Complement Med

January 2025

Research Consultant to Subtle Energy Funders Collective, Warwick, New York, USA.

Biofield Therapies, with a historical lineage spanning millennia and continuing relevance in contemporary practices, have been used to address various health conditions and promote wellbeing. The scientific study and adoption of these therapies have been hindered by cultural challenges and institutional barriers. In addition, the current research landscape for Biofield Therapies is insufficiently documented.

View Article and Find Full Text PDF

Targeting Kv7 Potassium Channels for Epilepsy.

CNS Drugs

January 2025

Division of Pharmacology, Department of Neuroscience, University of Naples "Federico II", Naples, Italy.

Voltage-gated Kv7 potassium channels, particularly Kv7.2 and Kv.7.

View Article and Find Full Text PDF

The Global Burden of Diseases (GBD) network has proposed theoretical minimum risk exposure level (TMREL) for leading risk factors associated with diet that minimize the risk of morbimortality from chronic diseases. TMREL can be applied to develop follow-up or evaluation indicators in individual studies. The validity of these scores can be tested by assessing associations with health outcomes in prospective cohorts.

View Article and Find Full Text PDF

Efficient extraction via titanium organic frameworks facilitates in-depth profiling of urinary exosome metabolite fingerprints.

Anal Bioanal Chem

January 2025

Department of Gastroenterology and Hepatology, Zhongshan Hospital, Department of Chemistry, Institutes of Biomedical Sciences, Fudan University, Shanghai, 200032, China.

Urinary exosome metabolite analysis has demonstrated notable advantages in uncovering disease status, yet its potential in decoding the intricacies of clear cell renal cell carcinoma (ccRCC) remains untapped. To address this, a core-shell magnetic titanium organic framework was designed to capture urinary exosomes and assist laser desorption/ionization mass spectrometry (LDI MS) to decipher the exosomal metabolic profile of ccRCC, with high sensitivity, throughput, and speed. A total of 492 urinary exosome metabolite fingerprints (UEMFs) from 176 samples were extracted for exploring the differences between ccRCC and healthy individuals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!