A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of organic and inorganic gunshot residues from hands using complexing agents and LC-MS/MS. | LitMetric

AI Article Synopsis

  • Gunshot residue (GSR) consists of both organic (OGSR) and inorganic species (IGSR), but previous methods primarily focused on identifying only IGSR particles.
  • This study proposes a new method using LC-MS/MS to detect both OGSR and IGSR in the same sample, improving detection confidence by reducing potential contamination from non-firearm sources.
  • The technique shows enhanced accuracy and efficiency, allowing analysis of both types of residues in under 20 minutes and expanding the range of detectable analytes compared to other existing methods.

Article Abstract

Gunshot residue (GSR) refers to a conglomerate consisting of both organic molecules (OGSR) and inorganic species (IGSR). Historically, forensic examiners have focused only on identifying the IGSR particles by their morphology and elemental composition. Nonetheless, modern ammunition formulations and challenges with the GSR transference (such as secondary and tertiary transfer) have driven research efforts for more comprehensive examinations, requiring alternative analytical techniques. This study proposes the use of LC-MS/MS for chromatographic separation and dual detection of inorganic and organic residues. The detection of both target species in the same sample increases the confidence that chemical profiles came from a gun's discharge instead of non-firearm-related sources. This strategy implements supramolecular molecules that complex with the IGSR species, allowing them to elute from the column towards the mass spectrometer while retaining isotopic ratios for quick and unambiguous identification. The macrocycle (18-crown-6-ether) complexes with lead and barium, while antimony complexes with a chelating agent (tartaric acid). The total analysis time for OGSR and IGSR in one sample is under 20 minutes. This manuscript expands from a previous proof-of-concept publication by improving figures of merit, increasing the target analytes, testing the method's feasibility through a more extensive set of authentic specimens collected from the hands of both shooters and non-shooters, and comparing performance with other analytical techniques such as ICP-MS, electrochemical methods and LIBS. The linear dynamic ranges (LDR) spread across the low ppb range for OGSR (0.3-200 ppb) and low ppm range (0.1-6.0 ppm) for IGSR. The method's accuracy increased overall when both organic and inorganic profiles were combined.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1ay00778eDOI Listing

Publication Analysis

Top Keywords

organic inorganic
8
analytical techniques
8
igsr
5
detection organic
4
inorganic
4
inorganic gunshot
4
gunshot residues
4
residues hands
4
hands complexing
4
complexing agents
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!