Background: Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction. However, previous studies had reported that the insertion of interference screws significantly caused graft laceration. The purposes of this study were to (1) quantitatively evaluate the graft laceration from one single insertion of PEEK interference screws; and (2) determine whether different types of sutures reduced the graft laceration after one single insertion of interference screws in ACL reconstruction.
Methods: The in-vitro ACL reconstruction model was created using porcine tibias and bovine extensor digitorum tendons of bovine hind limbs. The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra-high molecular weight polyethylene (UHMWPE) sutures. Poly-ether-ether-ketone (PEEK) interference screws were used for tibial fixation. This study was divided into five groups (n = 10 in each group): the non-fixed group, the non-sutured group, the absorbable suture group, the Ethibond suture group and the UHMWPE suture group. Biomechanical tests were performed using the mode of pull-to-failure loading tests at 10 mm/min. Tensile stiffness (newtons per millimeter), energy absorbed to failure (in joules) and ultimate load (newtons) were recorded for analysis.
Results: All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre-tension of the tendons, tibial bone mineral density) among all groups (P > 0.05). The biomechanical tests demonstrated that PEEK interference screws significantly caused the graft laceration (P < 0.05). However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction (P > 0.05).
Conclusions: Our biomechanical study suggested that the ultimate failure load of grafts was reduced of approximately 25 % after one single insertion of a PEEK interference screw in ACL reconstruction. Suturing the ends of the grafts using different sutures (absorbable, Ethibond and UHMWPE sutures) did not decrease the graft laceration caused by interference screws.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218482 | PMC |
http://dx.doi.org/10.1186/s12891-021-04457-5 | DOI Listing |
Cureus
November 2024
Plastic and Reconstructive Surgery, Middletown Aesthetics and Plastic Surgery, Middletown, USA.
Dog bites are one of the most common injuries in the United States, with varying presentations such as avulsion injuries and lacerations, and they range from a single bite to multiple bites in a victim. The severity of the dog bite is often the biggest factor in determining the treatment course. This report discusses the treatment of a 60-year-old male with severe facial avulsion trauma from a dog bite.
View Article and Find Full Text PDFJ Hand Surg Glob Online
November 2024
Department of Orthopedic Surgery, Texas Tech University of Health Sciences Center, Lubbock, TX.
Purpose: In the adult literature, allograft reconstruction of gapped peripheral nerve injuries has gained popularity over autologous nerve grafting. Allografts have demonstrated similar recovery while eliminating donor site morbidity. There is no well-defined incidence or treatment of such injuries in children.
View Article and Find Full Text PDFActa Chir Belg
December 2024
Department of Surgery, Charles University, University Hospital Hradec Králové, Hradec Králové, Czech Republic.
Int J Surg Case Rep
January 2025
Jinka University, department of statistics, Jinka, Ethiopia.
Introduction And Importance: Traumatic injuries of the inferior Vena Cava (IVC) are rare among traumatic abdominal injuries. It accounts for fewer than 5 % of penetrating injuries and 0.5 % of blunt trauma injuries.
View Article and Find Full Text PDFSurg Case Rep
November 2024
Department of Cardiovascular Surgery, Kumamoto University Hospital, Kumamoto, Japan.
Background: On-pump beating coronary artery bypass grafting (CABG) is a procedure that uses cardiopulmonary bypass to maintain circulation and it is a useful technique for CABG in patients with severely impaired cardiac function. Here, we report a case of left atrial rupture that occurred during CABG. Reports of left atrial injury are rare, and there have been no previous reports of such cases associated with on-pump beating CABG.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!