Silicone is widely used in chronic implants and is generally perceived to be safe. However, textured breast implants have been associated with immune-related complications, including malignancies. Here, by examining for up to one year the foreign body response and capsular fibrosis triggered by miniaturized or full-scale clinically approved breast implants with different surface topography (average roughness, 0-90 μm) placed in the mammary fat pads of mice or rabbits, respectively, we show that surface topography mediates immune responses to the implants. We also show that the surface surrounding human breast implants collected during revision surgeries also differentially alters the individual's immune responses to the implant. Moreover, miniaturized implants with an average roughness of 4 μm can largely suppress the foreign body response and fibrosis (but not in T-cell-deficient mice), and that tissue surrounding these implants displayed higher levels of immunosuppressive FOXP3 regulatory T cells. Our findings suggest that, amongst the topographies investigated, implants with an average roughness of 4 μm provoke the least amount of inflammation and foreign body response.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41551-021-00739-4DOI Listing

Publication Analysis

Top Keywords

breast implants
16
foreign body
16
body response
16
surface topography
12
average roughness
12
implants
9
mice rabbits
8
implants surface
8
immune responses
8
implants average
8

Similar Publications

Transcriptome of capsular contracture around breast implants mimics allograft rejection: a matched case-control study.

Plast Reconstr Surg

December 2024

Copenhagen University Hospital, Department of Plastic Surgery and Burns Treatment, Rigshospitalet, Copenhagen, Denmark.

Background: Capsular contracture is a frequent and severe complication following breast implant surgery. Although several theories on the pathophysiology exist, the exact molecular mechanisms remain unclear. This study aimed to identify the specific genes, signaling pathways, and immune cells associated with capsular contracture.

View Article and Find Full Text PDF

Faster Acquisition and Improved Image Quality of T2-Weighted Dixon Breast MRI at 3T Using Deep Learning: A Prospective Study.

Korean J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

Objective: The aim of this study was to compare image quality features and lesion characteristics between a faster deep learning (DL) reconstructed T2-weighted (T2-w) fast spin-echo (FSE) Dixon sequence with super-resolution (T2) and a conventional T2-w FSE Dixon sequence (T2) for breast magnetic resonance imaging (MRI).

Materials And Methods: This prospective study was conducted between November 2022 and April 2023 using a 3T scanner. Both T2 and T2 sequences were acquired for each patient.

View Article and Find Full Text PDF

Biomimetic Cerium-Assisted Supra-Carbon Dots Assembly for Reactive Oxygen Species-Activated Atherosclerosis Theranostic.

Small

January 2025

Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing University Three Gorges Hospital, Chongqing, 400044, China.

Theranostic applications in atherosclerosis plaque microenvironment-triggered nanoplatforms are significantly compromised by the complex synthesis procedure, non-specific distribution, and limited therapeutic function. Therefore, development of a facile and feasible method to construct a pathology-based stimuli-responsive nanoplatform with satisfactory theranostic performance remains a demanding and highly anticipated goal. Herein, a novel class of multifunctional supra-carbon dots (CDs), denoted as MM@Ce-CDs NPs, by a simple nanoassembly and a subsequent coating with macrophage membrane (MM), is developed for the targeted reactive oxygen species-trigged theranostic and positive regulation of the pathological plaque microenvironment in AS.

View Article and Find Full Text PDF

Capsular contracture (CC) is a concerning issue for individuals undergoing postmastectomy radiation therapy (PMRT) with implant-based breast reconstruction. This study investigated whether the extent of CC and implant migration differs based on implant placement and the reconstruction stage. Insertion plane and stage of breast implants were investigated, and the presence and severe cases of CC and implant migration were analyzed.

View Article and Find Full Text PDF

Systemic siliconomas following breast implant rupture.

BMJ Case Rep

January 2025

General Surgery, Universidade de Lisboa Faculdade de Medicina, Lisboa, Portugal.

We report a case of a woman in her late 40s with a history of breast implant surgery following breast cancer treatment. She presented with asymmetrical breast enlargement, palpable contralateral axillary lymph nodes and cutaneous nodules on both forearms. In addition, imaging evaluation revealed intracapsular implant rupture, ipsilateral internal mammary enlarged lymph nodes and multiple mediastinal lymphadenopathies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!