Objective: Essential tremor (ET) and Parkinsonian tremor (PT) are often clinically misdiagnosed due to the overlapping characteristics of their hand tremor. We aim to examine if ET and PT influence the multiscale dynamics of hand tremor, as quantified using complexity, differently, and if such complexity metric is of promise to help identify ET from PT.
Methods: Forty-eight participants with PT and 48 with ET performed two 30-second tests within each of the following conditions: sitting while resting arms or outstretching arms horizontally. The hand tremor was captured by accelerometers secured to the dorsum of each hand. The complexity was quantified using multiscale entropy.
Results: Compared to PT group, ET group had lower complexity of both hands across conditions (F > 34.2, p < 0.001). Lower complexity was associated with longer disease duration (r > 0.15, p < 0.009) in both PT and ET, and within PT, greater Unified Parkinson's Disease Rating Scale-III UPDRS-III scores (r > 0.18, p < 0.009). Receiver-operating-characteristic curves revealed that the complexity metric can distinguish ET from PT (area-under-the-curve > 0.77, cut-off value = 48 (postural), 49 (resting)), which was confirmed in a separate dataset with ET and PT that were clearly diagnosed in prior work.
Conclusions: The PT and ET have different effects on hand tremor complexity, and this metric is promising to help the identification of ET and PT, which still needs to be confirmed in future studies.
Significance: The characteristics of multiscale dynamics of the hand tremor, as quantified by complexity, provides novel insights into the different pathophysiology between ET and PT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clinph.2021.04.017 | DOI Listing |
Neurol Ther
January 2025
Department of Neurology, Rambam Health Care Campus, Haifa, Israel.
Background: Tremor in essential tremor and in tremor-dominant Parkinson's disease is assessed by subjective observations in patients undergoing focused ultrasound thalamotomy, a minimally invasive procedure intended to alleviate tremor in these patients.
Objective: To develop an objective tool for tremor analysis to be used before and after focused ultrasound thalamotomy treatment in the treated hand (contralateral to ablation) and non-treated (ipsilateral to ablation).
Methods: Using image processing and signal processing that utilized images of a Archimedes spiral drawing, we created a tool to analyze tremor.
J Minim Invasive Gynecol
January 2025
Department of Obstetrics and Gynecology, Kurashiki Medical Center, Okayama, Japan.
Objective: Recent advancements of minimally invasive gynecologic surgery have led to the development of transvaginal natural orifice translumenal endoscopic surgery (vNOTES) [1,2]. Robot-assisted vNOTES has also been explored as a method providing accurate and fine surgical procedures with improved ergonomics, visualization, wristed instruments, elimination of the hand tremor [3,4]. The objective of this video is to demonstrate the technical and anatomical highlights of a vaginal assisted NOTES hysterectomy (VANH) using the da Vinci SP (SP).
View Article and Find Full Text PDFAnn Clin Transl Neurol
January 2025
Section of Pediatric Neurology and Developmental Neuroscience, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, 77030, USA.
Objective: Rett syndrome (RTT) and MECP2 duplication syndrome (MDS) result from under- and overexpression of MECP2, respectively. Preclinical studies using genetic-based treatment showed robust phenotype recovery for both MDS and RTT. However, there is a risk of converting MDS to RTT, or vice versa, if accurate MeCP2 levels are not achieved.
View Article and Find Full Text PDFISA Trans
January 2025
School of Electronics Engineering, Kyungpook National University, Daegu 41566, Republic of Korea. Electronic address:
Hand-held robotic instruments enhance precision in microsurgery by mitigating physiological tremor in real time. Current tremor filtering algorithms in these instruments often employ nonlinear phase prefilters to isolate the tremor signal. However, these filters introduce phase distortion in the filtered tremor, compromising accuracy.
View Article and Find Full Text PDFWearable Technol
December 2024
Robotics Research Centre, School of Mechanical and Aerospace Engineering, NTU, Singapore.
Pathological tremors can often be debilitating to activities of daily living and significantly affect the quality of life. Such tremulous movements are commonly observed in wrist flexion-extension (FE). To suppress this tremor we present a wearable robot (WR) with a customized mechanical metamaterial (MM) as the physical human-robot interface (pHRI).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!