Nocturnal oximetry in the diagnosis of obstructive sleep apnea syndrome in potentially hypoxic patients due to neuromuscular diseases.

Sleep Med

Department of Specialized Medicine - Discipline of Otorhinolaryngology, School of Medicine and Surgery, Federal University of Rio de Janeiro State, Sleep Laboratory at Gafrée e Guinle University Hospital / UNIRIO, Brazil; LabSono - Sleep Laboratory of Gafrée and Guinle Hospital / UNIRIO, Mariz e Barros Street, 775, Tijuca, Rio de Janeiro, RJ, Brazil. Electronic address:

Published: August 2021

Introduction: Polysomnography is the recommended method for the diagnosis of obstructive sleep apnea (OSA); however, it is expensive, uncomfortable, and inaccessible. Alternative diagnostic methods are necessary, and Nocturnal Oximetry (NO) has proven to be reliable. Nevertheless, there have been doubts about its accuracy in patients with a history of hypoxia. Hence, the objective of this study was to evaluate the performance of NO in patients with neuromuscular diseases (NMD).

Method: This was a cross-sectional study in patients with NMD suspected of having OSA. We performed a statistical analysis using Spearman's correlation coefficients (SCCs). We used the value of the area under the ROC curve (AUCROC), just as we calculated the sensitivities (Sens) and specificities (Spec) for the chosen variables.

Results: The sample comprised 41 patients; 51.2% with muscular dystrophies and 48.8% with motor neuron diseases, with a predominance of men (63.4%). Median age was 42 (19.7-55) years, body mass index (BMI) was 27.9 (23.8-32) kg/m2, forced vital capacity was 67% (54%-76.5%), and maximum inspiratory pressure was-60 cmH2O (-87.5 to -50). The prevalence of OSA was 75.7%. We analyzed and selected the best four oximetric variables with the following performance in identifying the apnea/hypopnea index >5/h, ODI3/2, cutoff>5/h, AUCROC 0.919, Sens 82.3%, Spec 91.7%; ODI3/5, cutoff>11.2/h, AUCROC 0.904, Sens 82.3%, Spec 87.5%; ODI4/5, cutoff>6.02, AUCROC 0.839, Sens 70.6%, Spec 91.6%, and ODI5/5, cutoff>0.87/h, AUCROC 0.870, Sens 94.1%, and Spec 70.8%.

Conclusion: NO can be used as a diagnostic tool for OSA, even in patients with neuromuscular diseases and potentially hypoxic diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.sleep.2021.05.009DOI Listing

Publication Analysis

Top Keywords

patients neuromuscular
12
neuromuscular diseases
12
nocturnal oximetry
8
diagnosis obstructive
8
obstructive sleep
8
sleep apnea
8
sens 823%
8
823% spec
8
patients
6
diseases
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!