A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A selective fluorescence sensor for hypochlorite used for the detection of hypochlorite in zebrafish. | LitMetric

A selective fluorescence sensor for hypochlorite used for the detection of hypochlorite in zebrafish.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Chemistry and Biochemistry, Brigham Young University, Provo 84602, UT, United States. Electronic address:

Published: November 2021

Hypochlorite is used as a water disinfectant and it is also produced by biological organisms. Its detection and quantification is important and could lead to its mechanism of reactivity in cells. We have synthesized a new fluorescence sensor for hypochlorite based on bithiophene and furan-carbohydrazide. The sensor shows increased fluorescence as a function of hypochlorite and is selective for hypochlorite. Fluorescence enhancement due to hypochlorite is observed when the sensor is used in aqueous solutions at neutral pH values. Using the sensor, the detection limit for hypochlorite is 4.2 µM, making the sensor practical to determine hypochlorite in water. Applying the sensor to aide in the detection of hypochlorite in zebrafish, showed localization of ClO/HClO in the air bladders and eyes of zebrafish.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2021.120059DOI Listing

Publication Analysis

Top Keywords

hypochlorite
10
fluorescence sensor
8
sensor hypochlorite
8
detection hypochlorite
8
hypochlorite zebrafish
8
hypochlorite water
8
sensor
7
selective fluorescence
4
detection
4
hypochlorite detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!