Purpose: The aim of this study was to evaluate differences in the iris and angle parameters in psuedoexfoliation syndrome (PXF) and pseudoexfoliation glaucoma (PXG) using anterior segment optical coherence tomography (ASOCT).

Methods: Patients with PXF or PXG were compared using ASOCT with primary open-angle glaucoma POAG eyes as controls in this noninterventional comparative study conducted at a tertiary eye care center in East India. All angle parameters, TM length, and iris thickness were analyzed from the enhanced depth imaging (EDI) single scans obtained. Quadrant scans were used for the calculation of iris volume using a custom-built in-house software. In particular, the software performs multiple operations including edge detection, connected components, and thresholding to localize and segment the iris. Differences in the iris volume/thickness and TM length in PXF and PXG with POAG were analyzed.

Results: A total of 225 eyes were included, which included 75 PXG and 98 PXF cases and 52 POAG with a mean age of 67 ± 9.7 years at presentation. The algorithm repeatability and reproducibility was also established with correlation coefficients more than 99% which was substantiated with Bland-Altman plots. The iris volume (calculated in 197 images of 225 eyes) did not differ significantly in PXF and PXG eyes, although both had significantly greater volume compared to POAG eyes. The iris volume or other angle parameters including TM length did not correlate with clinical variables such as IOP, age, or visual field indices.

Conclusion: Iris parameters or TM length do not explain pathogenesis of glaucoma in pseudoexfoliation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374829PMC
http://dx.doi.org/10.4103/ijo.IJO_2403_20DOI Listing

Publication Analysis

Top Keywords

iris volume
16
angle parameters
12
pxf pxg
12
anterior segment
8
segment optical
8
optical coherence
8
coherence tomography
8
pseudoexfoliation glaucoma
8
iris
8
differences iris
8

Similar Publications

Purpose: Using a fully automated multitask deep learning method, which enabled simultaneous segmentation and quantification of all major anterior segment structures with swept-source optical coherence tomography (SS-OCT), we aimed to investigate the three-dimensional (3D) alterations in iris morphology before and after implantable collamer lens (ICL) surgery.

Methods: All enrolled patients underwent anterior segment SS-OCT (ANTERION) within one week before and after ICL surgery. A multitask network automatically performed iris SS-OCT image segmentation and quantitative measurements of 3D iris morphology (iris thickness and volume of the inner 1-mm annular area and the outer 1-2-mm annular area, iris curvature [I-Curve], and iris smooth index [SI]).

View Article and Find Full Text PDF

Aβ42 biomarker linked to insula, striatum, thalamus and claustrum in dementia with Lewy bodies.

Geroscience

January 2025

ICube Laboratory UMR-7357 and FMTS (Fédération de Médecine Translationnelle de Strasbourg), IMIS Team and IRIS Platform, University of Strasbourg and CNRS, Strasbourg, France.

The differential mechanisms between proteinopathies and neurodegeneration in Alzheimer's disease (AD) and dementia with Lewy bodies (DLB) remain unclear. To address this issue, we conducted a voxel-based morphometry and cerebrospinal fluid biomarker (α-synuclein, Aβ42, t-Tau and p-Tau) level correlation study in patients with DLB, AD and mixed cases (AD + DLB). Cerebrospinal fluid samples obtained by lumbar puncture and whole-brain T1-weighted images were collected in the AlphaLewyMA cohort.

View Article and Find Full Text PDF

Background: There are no approved oral disease-modifying treatments for Alzheimer's disease (AD).

Objectives: The objective of this study was to assess efficacy and safety of blarcamesine (ANAVEX®2-73), an orally available small-molecule activator of the sigma-1 receptor (SIGMAR1) in early AD through restoration of cellular homeostasis including autophagy enhancement.

Design: ANAVEX2-73-AD-004 was a randomized, double-blind, placebo-controlled, 48-week Phase IIb/III trial.

View Article and Find Full Text PDF

Objective: To evaluate the repeatability of AI-based automatic measurement of vertebral and cardiovascular markers on low-dose chest CT.

Methods: We included participants of the population-based Imaging in Lifelines (ImaLife) study with low-dose chest CT at baseline and 3-4 month follow-up. An AI system (AI-Rad Companion chest CT prototype) performed automatic segmentation and quantification of vertebral height and density, aortic diameters, heart volume (cardiac chambers plus pericardial fat), and coronary artery calcium volume (CACV).

View Article and Find Full Text PDF

Photodegradation of steroid hormone micropollutants with palladium-porphyrin coated porous PTFE of varied morphological and optical properties.

Water Res

December 2024

Institute for Advanced Membrane Technology (IAMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany. Electronic address:

In flow-through reactors, the photodegradation rate can be improved by enhancing contact and increasing the photocatalyst loading. Both can be attained with a higher surface-to-volume ratio. While previous studies focused on thin membranes (30 - 130 µm) with small pore sizes of 20 - 650 nm, this work employed poly(tetrafluoroethylene) (PTFE) supports, of which pore sizes are in the order of 10 µm, while the porosities and thicknesses are variable (22.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!