Objectives: The aim of this study was to investigate the effect of cartilage thickness mismatch on tibiotalar articular contact pressure in osteochondral grafting from femoral condyles to medial talar dome using a finite element analysis (FEA).
Materials And Methods: Flush-implanted osteochondral grafting was performed on the talar centromedial aspect of the dome using osteochondral plugs with two different cartilage thicknesses. One of the plugs had an equal cartilage thickness with the recipient talar cartilage and the second plug had a thicker cartilage representing a plug harvested from the knee. The ankle joint was loaded during a single-leg stance phase of gait. Tibiotalar contact pressure, frictional stress, equivalent stress (von Mises values), and deformation were analyzed.
Results: In both osteochondral grafting simulations, tibiotalar contact pressure, frictional stress, equivalent stress (von Mises values) on both tibial and talar cartilage surfaces were restored to near-normal values.
Conclusion: Cartilage thickness mismatch does not significantly change the tibiotalar contact biomechanics, when the graft is inserted flush with the talar cartilage surface.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8343842 | PMC |
http://dx.doi.org/10.52312/jdrs.2021.41 | DOI Listing |
Food Sci Nutr
January 2025
Department of Physiology, College of Medicine Gyeongsang National University Jinju Republic of Korea.
Our previous study highlighted the anticancer potential of sea hare hydrolysate (SHH), particularly its role in regulating macrophage polarization and inducing pyroptotic death in lung cancer cells through the inhibition of signal transducer and activator of transcription 3 (STAT3). These findings prompted us to investigate additional features of immune-oncology (I-O) agents or adjuvants, such as programmed cell death protein 1 (PD-1)/programmed death ligand 1 (PD-L1) inhibition and their association with rheumatoid arthritis (RA) risk, to explore the potential of SHH as an I-O agent or adjuvant. In this study, we investigated the effects of SHH on PD-L1 levels in various cancer cell types and assessed its effectiveness in treating RA, a common side effect of I-O agents.
View Article and Find Full Text PDFOsteoarthr Cartil Open
March 2025
Department of Mechanical Engineering and Materials Science, Duke University, United States.
Objective: We sought to measure the deformation of tibiofemoral cartilage immediately following a 3-mile treadmill run, as well as the recovery of cartilage thickness the following day. To enable these measurements, we developed and validated deep learning models to automate tibiofemoral cartilage and bone segmentation from double-echo steady-state magnetic resonance imaging (MRI) scans.
Design: Eight asymptomatic male participants arrived at 7 a.
Arch Orthop Trauma Surg
January 2025
Institute for Locomotion, Aix-Marseille University, Marseille, France.
Introduction: The aim of this study was to establish an international consensus statement on the indications for the addition of a patellofemoral joint arthroplasty (PFJA) in patients with a unicondylar knee arthroplasty (UKA) and symptomatic progression of patellofemoral compartment osteoarthritis.
Materials And Methods: A systematic review of the literature was conducted, and the results used to inform the development of a statement by an expert working group. This was then evaluated and modified, using a Delphi process, by members of the European Knee Society (EKS).
Magn Reson Imaging
January 2025
Department of Radiology, University Hospital of Strasbourg, 1 Avenue Moliere, 67098 Strasbourg, France.
Purpose: Compressed Sensing (CS) is an emerging technique to accelerate MRI acquisitions. The aim of this study was to assess the reliability and accuracy of cartilage thickness measurements in the knee using a CS-enabled isotropic 3D Fast Spin-Echo (FSE) sequence on a 3-T MRI scanner.
Methods: Twenty-eight tibial condyle sections were collected from 14 adult patients who underwent total knee arthroplasty.
Proc Inst Mech Eng H
January 2025
Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK.
Subject-specific finite element models of knee joint contact mechanics are used in assessment of interventions and disease states. Cartilage thickness distribution is one factor influencing the distribution of pressure. Precision of cartilage geometry capture varies between imaging protocols.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!