We present a method for calibration and data extraction for a Stokes polarimeter working with three different wavelengths simultaneously. In the Stokes polarimeter considered in this work, we use two liquid crystal variable retarders (LCVRs) combined with a Glan-Thompson linear polarizer. A recently developed fitting calibration procedure is used. We use the same calibration samples and LCVR voltages for all three wavelengths, giving simultaneous measurement and calibration. We compare the performance of the polarimeter, after calibration, using four or six calibration samples in our experiment. To generate the four known calibration beams, we use a linear polarizer oriented at 130° and 30° with respect to the horizontal, a horizontal linear polarizer followed by a half-wave plate (at 632 nm) with its fast axis at 30°, and a horizontal linear polarizer followed by a quarter-wave plate (at 632 nm) with its fast axis at 30°. For calibration with six reference beams, we add two known calibration beams by setting the fast axis of the half- and quarter-wave plates at 130°. Experimental results show good agreement with the expected results, with the fitting calibration procedure giving an approximately 50% reduction in total RMS error with four calibration samples. There is a negligible reduction in the error when six calibration samples are used compared to the case with four samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.430687 | DOI Listing |
Sci Adv
January 2025
Jodrell Bank Centre for Astrophysics, Department of Physics and Astronomy, The University of Manchester, Oxford Road, Manchester, M13 9PL, UK.
Long-period radio transients are a new class of astrophysical objects that exhibit periodic radio emission on timescales of tens of minutes. Their true nature remains unknown; possibilities include magnetic white dwarfs, binary systems, or long-period magnetars; the latter class is predicted to produce fast radio bursts (FRBs). Using the MeerKAT radio telescope, we conducted follow-up observations of the long-period radio transient GPM J1839-10.
View Article and Find Full Text PDFJ Anat
January 2025
Bonn Institute of Organismal Biology, Paleontology, University of Bonn, Bonn, Germany.
Current understanding of the histology of the dermoskeleton of tetrapods comes from fossilized and recent remains of skulls, osteoderms, carapace, plastron and other postcranial material which were always investigated using linear cross polarized light (LCPL) microscopy. The pectoral girdle of vast majority of non-amniote tetrapods, including temnospondyls evolved large ventrally located dermal bones- the interclavicle and a pair of clavicles. Despite that, there is a lack of information about the bone tissue structure from these postcranial dermal bones.
View Article and Find Full Text PDFPNAS Nexus
January 2025
Department of Communication, Cornell University, Ithaca, NY 14853, USA.
Researchers have raised concerns that messages describing racial disparities in social outcomes can reduce or polarize support for public policies to address inequality. We questioned this assumption by testing the impact of carefully crafted messages about child tax credit (CTC) expansion. We conducted two randomized message trials, study 1 using Prolific's nonprobability panel ( = 1,402) and study 2 using SSRS's Opinion Panel, a web-based probability sample of US adults ( = 4,483).
View Article and Find Full Text PDFMacromol Rapid Commun
January 2025
School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 62 Nanyang Drive, Singapore, 637459, Singapore.
A series of biomass-based linear aliphatic polyesters are synthesized by combining sebacic acid (SA) (C10 diacid) and 1,18-octadecanedioic acid (OA) (C18 diacid) with a series of diols with varied alkyl chain lengths (C2 to C10 diols). SA and OA are obtainable from castor oil and palm oil, respectively. The reaction extent (polymerization extent) is high (≥96%) in all cases, and the number-average molecular weight (M) is 10 000-43 000 g mol after purification.
View Article and Find Full Text PDFBiomed Opt Express
January 2025
School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
Radiation therapy (RT) is widely used for cancer treatment but is found with side effects of radiation dermatitis and fibrosis thereby calling for timely assessment. Nevertheless, current clinical assessment methods are found to be subjective, prone to bias, and accompanied by variability. There is, therefore, an unmet clinical need to explore a new assessment technique, ideally portable and affordable, making it accessible to less developed regions too.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!