Introduction: Osteoid osteoma (OO) is a common tumor of the diaphysis of long bone, where the reported incidence is up 10% of all benign bone tumors. Its presence in flat bone is seldom mentioned in literature and can be misleading when the bone involved is in proximity to a zone of wide variety of possible pathology. We report a case of a young patient with OO in a very rare location of the body -the scapular neck - that was misdiagnosed for a long period of time before receiving adequate therapy.
Case Report: A 20-year-old female patient presented to the clinic with chronic left shoulder pain. During the past 2 years, she received medical and physical therapy, to deal with different diagnosis such as cervical spine pathology, muscular spasm, and rotator cuff disease. However, she did not improve. At time of presentation to our clinic, radiographs of the shoulder were done and turned to be inconclusively normal. After negative magnetic resonance imaging of the cervical spine, a computed tomography scan of the shoulder was done and showed a round well-defined lesion localized in the scapular neck with a focal lucent nidus within surrounding sclerotic reactive bone measuring 8.5 mm in largest diameter, compatible with OO. Bone scan showed increased uptake. The patient was given aspirin in an intention to test and treat. The patient had dramatic pain relieve at first, which confirmed the diagnosis of OO. But then, pain became unremitting, so a decision was made for radiofrequency ablation of the lesion which gave excellent results.
Conclusion: OO is a common benign neoplasm with high variable clinical picture and anatomic localization. Despite being more common in long bone, flat bone OO localization should be always kept in mind. Careful history and physical examination should be done for each patient presenting with unexplained pain; night pain should always raise suspicion of this condition. Radiographs are not always conclusive, and the patient with high suspicion of this condition should undergo more investigation to make the diagnosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8180340 | PMC |
http://dx.doi.org/10.13107/jocr.2021.v11.i02.2020 | DOI Listing |
J Clin Med
January 2025
Shoulder and Elbow Surgery, Schulthess Clinic Zürich, 8008 Zürich, Switzerland.
: Classical reverse shoulder arthroplasty (RSA) with a high neck-shaft angle (NSA) of 155° has shown satisfactory outcomes. However, newer RSA designs aim to improve results by modifying the stem design. This study evaluates the 5-year outcomes of a stem design featuring a rectangular metadiaphyseal fixation and a 135° NSA.
View Article and Find Full Text PDFHead Neck
January 2025
Division of Otolaryngology, Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
Background: Virtual surgical planning (VSP) with simple cutting templates could help surgeons preoperatively plan scapula reconstructions in the vertical and horizontal orientations.
Methods: Virtually, eight defects were created in ten healthy mandibles and reconstructed with the subject-specific scapula vertically and horizontally. In the clinical series, 15 single-piece scapula mandible reconstructions planned with in-house VSP and guided with simple templates were compared with 15 freehand reconstructions.
Clin Biomech (Bristol)
January 2025
Health Sciences Department, Ribeirão Preto Medical School, University of São Paulo, Brazil.
Background: Upper limb fractures significantly alter movement, impacting function and recovery. Three-dimensional motion analysis allows precise assessment of these changes.
Methods: Sixty patients were divided into four groups: shoulder, elbow, wrist fractures, and controls.
Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.
Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.
Curr Rev Musculoskelet Med
January 2025
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
Purpose Of Review: With the growing popularity and broadening indications for Reverse Shoulder Arthroplasty (RSA), increasing modularity in design and adjustments to each component can enhance postoperative range of motion (ROM), thus expanding treatment capabilities. This review outlines the advancements developed to optimize ROM through modifications in glenoid and humeral components and the integration of computational tools for surgical planning.
Recent Findings: Enhancements in glenoid component design aim to mitigate complications like scapular notching and improve ROM, particularly in abduction and external rotation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!