Background: It is expected that ablation procedures will be increasingly offered to a more aged population affected with persistent AF (persAF); however, the clinical outcomes of ablation in this specific population are not well described. We aimed to analyze the efficacy and safety of CB-A in this group of patients compared with a younger cohort.
Methods And Results: Eighty-three patients with (persAF) aged ≥75 years (group 1; mean age 78.2 ± 3.1 years) and 166 patients also affected with persAF aged <75 years (group 2; mean age 64.3 ± 6.6 years) were included in the study. The primary outcome was freedom from recurrent sustained (>30 seconds) atrial arrhythmias without anti-arrhythmic medication after a blanking period of 3 months. At 2 years, clinical success was achieved in 108 out of 249 patients (43.4%). Median follow-up was 24 months (IQR: 18.4-25.5 months). Older patients suffered from more recurrences than those in the younger cohort ((53/83 patients, 63.9% vs 88/166 patients, 53.0%; = .03). Thirty (12.0%) patients suffered a complication, but the incidence of complications was not different between both groups. The most frequent complication was transient phrenic nerve injury.
Conclusions: The global 2 years efficacy of CB-A PVI in persAF is 43.4%. A lower success rate is achieved in the older patients (36.1%) compared to the younger age group (47.0%). However, the complication rate was not different between age groups.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8207396 | PMC |
http://dx.doi.org/10.1002/joa3.12531 | DOI Listing |
Drug Alcohol Depend
January 2025
RAND, Boston, MA, United States. Electronic address:
Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.
Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.
Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.
Comput Med Imaging Graph
January 2025
CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:
In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Eur J Radiol
January 2025
Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:
Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.
View Article and Find Full Text PDFEur J Radiol
January 2025
Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:
Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.
Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!