Background: A novel measurement of the local impedance (LI) and electrograms recorded from micro-electrodes on catheter tip has been developed. However, the data during pulmonary vein (PV) ablation is not sufficient. We aimed to investigate the utility of this measurement during initial atrial fibrillation (AF) ablation.
Methods: We investigated 111 representative radiofrequency applications in 7 AF patients without a history of prior ablation (6 males, age 68 [65-72] years, 2 persistent AF). The ablation strategy was PV isolation for paroxysmal AF and single ring box isolation for persistent AF, using MiFi catheter. The correlation of the generator impedance (GI) drop and LI drop after radiofrequency applications and the predictive value of the initial LI elevation before radiofrequency applications for LI drop were analyzed. Also, the LI and GI drop were investigated according to the location of RF applications.
Results: The LI drop was higher than GI drop (23.7 [16.4-35.7] and 9.0 [6.0-12.0]; < .01). There were correlations between the initial LI elevation and LI drop ( = 0.466, < .01) and between the LI and GI drop ( = 0.263, < .01). The LI drops significantly differed according to the different anatomical localizations by the Kruskal-Wallis test, although the GI drops did not differ ( < .01 and = .49, respectively).
Conclusion: LI drop was associated with initial LI elevation and was larger than GI drop. LI drop was different according to locations, although GI drop was not. These findings might indicate that LI drop would be a more sensitive marker for lesion formation than GI drop.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8207389 | PMC |
http://dx.doi.org/10.1002/joa3.12535 | DOI Listing |
Nat Commun
December 2024
Department of Electrical and Computer Engineering, Princeton University, Princeton, NJ, USA.
Millimeter-wave and terahertz integrated circuits and chips are expected to serve as the backbone for future wireless networks and high resolution sensing. However, design of these integrated circuits and chips can be quite complex, requiring years of human expertise, careful tailoring of hand crafted circuit topologies and co-design with parameterized and pre-selected templates of electromagnetic structures. These structures (radiative and non-radiative, single-port and multi-ports) are subsequently optimized through ad-hoc methods and parameter sweeps.
View Article and Find Full Text PDFJ Cosmet Dermatol
January 2025
Department of Plastic and Reconstructive Surgery, Senior Department of Burns and Plastic Surgery, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China.
Background: Hypertrophic scar (HS) is a fibroproliferative disorder resulting from abnormal healing of skin tissue after injury. Although various therapies are currently employed in clinical to treat HSs, there is no widely accepted standard therapy. Micro-plasma radiofrequency (MPR) and autologous chyle fat grafting are emerging treatments for this condition, and they have demonstrated promising therapeutic outcomes in clinical applications.
View Article and Find Full Text PDFJ Biomed Phys Eng
December 2024
Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Background: T thermometry is considered a straight method for the safety monitoring of patients with deep brain stimulation (DBS) electrodes against radiofrequency-induced heating during Magnetic Resonance Imaging (MRI), requiring different sequences and methods.
Objective: This study aimed to compare two T thermometry methods and two low specific absorption rate (SAR) imaging sequences in terms of the output image quality.
Material And Methods: In this experimental study, a gel phantom was prepared, resembling the brain tissue properties with a copper wire inside.
Expert Rev Med Devices
December 2024
NorthShore University Health System, Evanston, IL, USA.
Introduction: Proactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4s. Varying power and duration however does not eliminate the risk of thermal injury.
View Article and Find Full Text PDFFront Netw Physiol
December 2024
Department of Physics, University of Alberta, Edmonton, AB, Canada.
A steadily increasing number of publications support the concept of physiological networks, and how cellular bioelectrical properties drive cell proliferation and cell synchronization. All cells, especially cancer cells, are known to possess characteristic electrical properties critical for physiological behavior, with major differences between normal and cancer cell counterparts. This opportunity can be explored as a novel treatment modality in Oncology.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!