Robust Potassium Isotopic Analysis of Geological and Biological Samples via Multicollector ICP-Mass Spectrometry Using the "Extra-High Resolution Mode".

Anal Chem

Atomic & Mass Spectrometry - A&MS research unit, Department of Chemistry, Ghent University, Campus Sterre, Krijgslaan 281 - S12, 9000 Ghent, Belgium.

Published: June 2021

Potassium isotopic analysis is arousing increasing interest, not only in geochemistry, but also in biomedicine. However, real-life applications are still hindered by the lack of robustness of the methods used. In this work, a novel and robust method for high-precision K isotopic analysis of geological and biological samples was developed, based on the use of a multicollector ICP-mass spectrometer providing a mass resolving power of 15,000 (extra-high resolution mode, XHR). After evaluation of different measurement conditions, , hot cold plasma conditions, standard-type jet-type sampling cone, and high resolution (HR) XHR, a combination of hot plasma conditions, use of the high-transmission jet-type sampling cone, and the XHR mode allowed for high-precision and interference-free K isotopic analysis. Potassium signal monitoring was performed in the ArH interference-free 0.006-0.007 amu wide peak shoulder using the XHR mode. The within-run, short-term external, and long-term external precisions for the δK value were 0.02‰ (2se, = 50), 0.03‰ (2SD, = 7), and 0.06‰ (2SD, = 163), respectively. A two-stage chromatographic procedure was developed for the isolation of K from both geological and biological samples, and potential matrix effects affecting the K isotope ratio were systematically evaluated. The method was first applied to geological reference materials (RMs) for validation purposes, and the K isotope ratio results were in good agreement with those previously reported. Subsequently, a series of biological RMs, including serum, whole blood, cerebrospinal fluid, bovine muscle, and lobster hepatopancreas, were characterized for their K isotopic composition.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.1c01087DOI Listing

Publication Analysis

Top Keywords

isotopic analysis
16
geological biological
12
biological samples
12
potassium isotopic
8
analysis geological
8
multicollector icp-mass
8
plasma conditions
8
jet-type sampling
8
sampling cone
8
xhr mode
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!