Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-021-02882-6DOI Listing

Publication Analysis

Top Keywords

prostatic artery
4
artery embolization
4
embolization polyzene-coated
4
polyzene-coated 100 µm
4
100 µm microspheres
4
microspheres resource-challenged
4
resource-challenged country
4
country initial
4
initial single-centre
4
single-centre experience
4

Similar Publications

Objectives: The primary aim of this study was to evaluate the effects of vasodilator administration on CT angiography (CTA) prostatic artery diameter and peak opacification in dogs with prostatic carcinoma prior to prostatic artery embolization (PAE).

Materials And Methods: A prospective clinical trial was performed. Ten dogs with naturally occurring prostatic carcinoma and no evidence of cardiovascular disease were enrolled.

View Article and Find Full Text PDF

A 79-year old Caucasian male with metastatic hormone refractory prostate cancer and bilateral nephrostomy was admitted to the emergency department due to 4-day bloody urethral discharge, weakness and dizziness. The patient was treated with the luteinizing hormone-releasing hormone-antagonist and abiraterone acetate plus prednisone, dabigatran 150 mg bid (for atrial fibrillation and coronary heart disease) and 5-aminosalicylic acid for the management of mild ulcerative colitis. Imaging revealed bladder overdistention and blood analysis low levels of hematocrit (HCT) and hemoglobin (HGB) (HCT, 22%; HGB, 7.

View Article and Find Full Text PDF

Nutcracker syndrome is caused by the compression of the left renal vein between the abdominal aorta and the superior mesenteric artery. The use of Doppler ultrasonography to diagnose this condition is challenging due to the dynamic nature of the nutcracker phenomenon and the variability of its symptoms, which can fluctuate with changes in patient posture and respiration. This review emphasizes the critical role of Doppler ultrasonography in identifying and managing nutcracker syndrome.

View Article and Find Full Text PDF

: We aimed to compare cone beam computed tomography (CBCT) utilization and radiation exposure during prostatic artery embolization (PAE) procedures on two different angiography systems. : PAEs performed by a single interventionalist between January 2018 and October 2020 on two multivendor angiography systems (AS1 and AS2) at a single center were retrospectively evaluated. Imaging techniques included CBCT acquisition when possible, predominantly from the distal aorta in AS1 and from the bilateral internal iliac arteries in AS2 (Discovery IGS 740, GE HealthCare, Chicago, IL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!