X-ray computed tomography (XCT) is a promising nondestructive evaluation technique for additive manufacturing (AM) parts with complex shapes. Industrial XCT scanning is a relatively new development, and XCT has several acquisition parameters that a user can change for a scan whose effects are not fully understood. An artifact incorporating simulated defects of different sizes was produced using laser powder bed fusion (LPBF) AM. The influence of six XCT acquisition parameters was investigated experimentally based on a fractional factorial designed experiment. Twenty experimental runs were performed. The noise level of the XCT images was affected by the acquisition parameters, and the importance of the acquisition parameters was ranked. The measurement results were further analyzed to understand the probability of detection (POD) of the simulated defects. The POD determination process is detailed, including estimation of the POD confidence limit curve using a bootstrap method. The results are interpreted in the context of the AM process and XCT acquisition parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200929PMC
http://dx.doi.org/10.1115/1.4044515DOI Listing

Publication Analysis

Top Keywords

acquisition parameters
24
xct acquisition
12
x-ray computed
8
computed tomography
8
probability detection
8
additive manufacturing
8
simulated defects
8
acquisition
6
parameters
6
xct
6

Similar Publications

In the realm of petroleum extraction, well productivity declines as reservoirs deplete, eventually reaching a point where continued extraction becomes economically unfeasible. To counteract this, artificial lift techniques are employed, with gas injection being a prevalent method. Ideally, unrestricted gas injection could maximize oil output.

View Article and Find Full Text PDF

Background And Purpose: Synthetic MRI utilizes the quantitative relaxometry parameters to generate multiple contrast images through a single acquisition. We tried to explore the utility of synthetic MRI derived relaxometry parameters in evaluation of ring enhancing lesions of brain.

Materials And Methods: This was a prospective study.

View Article and Find Full Text PDF

The accurate measurement of spatiotemporal parameters, such as step length and step frequency, is crucial for analyzing running and sprinting performance. Traditional methods like video analysis and force platforms are either time consuming or limited in scope, prompting the need for more efficient technologies. This study evaluates the effectiveness of a commercial Global Positioning System (GPS) unit integrated with an Inertial Measurement Unit (IMU) in capturing these parameters during sprints at varying velocities.

View Article and Find Full Text PDF

Biomimetic Active Stereo Camera System with Variable FOV.

Biomimetics (Basel)

December 2024

School of Mechanical Engineering and Automation, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China.

Inspired by the biological eye movements of fish such as pipefish and sandlances, this paper presents a novel dynamic calibration method specifically for active stereo vision systems to address the challenges of active cameras with varying fields of view (FOVs). By integrating static calibration based on camera rotation angles with dynamic updates of extrinsic parameters, the method leverages relative pose adjustments between the rotation axis and cameras to update extrinsic parameters continuously in real-time. It facilitates epipolar rectification as the FOV changes, and enables precise disparity computation and accurate depth information acquisition.

View Article and Find Full Text PDF

Normothermic machine perfusion (NMP) facilitates utilization of marginal liver allografts. It remains unknown whether clinical benefits offset additional costs in the real-world setting. We performed a comparison of outcomes and hospitalization costs for donor livers preserved by NMP versus static cold storage (SCS) at a high-volume center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!