The natural fluorescence (autofluorescence) of tissues has been noted as a biomarker for cancer for several decades. Autofluorescence contrast between tumors and healthy tissues has been of significant interest in endoscopy, leading to development of autofluorescence endoscopes capable of visualizing 2-3 fluorescence emission wavelengths to achieve maximal contrast. However, tumor detection with autofluorescence endoscopes is hindered by low fluorescence signal and limited quantitative information, resulting in prolonged endoscopic procedures, prohibitive acquisition times, and reduced specificity of detection. Our lab has designed a novel excitation-scanning hyperspectral imaging system with high fluorescence signal detection, low acquisition time, and enhanced spectral discrimination. In this study, we surveyed a comprehensive set of excised tissues to assess the feasibility of detecting tissue-specific pathologies using excitation-scanning. Fresh, untreated tissue specimens were imaged from 360 to 550 nm on an inverted fluorescence microscope equipped with a set of thin-film tunable filters (Semrock, A Unit of IDEX). Images were subdivided into training and test sets. Automated endmember extraction (ENVI 5.1, Exelis) with PCA identified endmembers within training images of autofluorescence. A spectral library was created from 9 endmembers. The library was used for identification of endmembers in test images. Our results suggest (1) spectral differentiation of multiple tissue types is possible using excitation scanning; (2) shared spectra between tissue types; and (3) the ability to identify unique morphological features in disparate tissues from shared autofluorescent components. Future work will focus on isolating specific molecular signatures present in tissue spectra, and elucidating the contribution of these signatures in pathologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8203318PMC
http://dx.doi.org/10.1117/12.2213214DOI Listing

Publication Analysis

Top Keywords

novel excitation-scanning
8
excitation-scanning hyperspectral
8
hyperspectral imaging
8
imaging system
8
autofluorescence endoscopes
8
fluorescence signal
8
tissue types
8
fluorescence
5
autofluorescence
5
feasibility detection
4

Similar Publications

Spectral intensity drift correction of Spark Mapping Analysis for large-size metal materials.

Anal Chim Acta

September 2024

Beijing Key Laboratory of Metal Materials Characterization, NCS Testing Technology Co., Ltd., Beijing, 100081, China.

Background: Spectral intensity drift is a frequent issue in analytical processes, especially in long time excitation scanning for large size metal materials, which can significantly adversely impact the accuracy and stability of analysis results. Spectral intensity drift correction is the process of preprocessing spectral data using mathematical algorithms in order to facilitate the subsequent qualitative and quantitative analysis of spectra, especially in combination with stoichiometric methods. Up to now, spectral intensity drift correction within prolonged excitation has not been reported yet.

View Article and Find Full Text PDF

Colorectal cancer is one of the top contributors to cancer-related deaths in the United States, with over 100,000 estimated cases in 2020 and over 50,000 deaths. The most common screening technique is minimally invasive colonoscopy using either reflected white light endoscopy or narrow-band imaging. However, current imaging modalities have only moderate sensitivity and specificity for lesion detection.

View Article and Find Full Text PDF

Hyperspectral imaging technologies (HSI) have undergone rapid development since their beginning stages. While original applications were in remote sensing, other uses include agriculture, food safety and medicine. HSI has shown great utility in fluorescence microscopy for detecting signatures from many fluorescent molecules; however, acquisitions speeds have been slow due to light losses associated with spectral filtering.

View Article and Find Full Text PDF

Colorectal cancer is the 3 leading cancer for incidence and mortality rates. Positive treatment outcomes have been associated with early detection; however, early stage lesions have limited contrast to surrounding mucosa. A potential technology to enhance early stagise detection is hyperspectral imaging (HSI).

View Article and Find Full Text PDF

Spectral Illumination System Utilizing Spherical Reflection Optics.

Proc SPIE Int Soc Opt Eng

February 2020

Department of Chemical and Biomolecular Engineering.

Fluorescence imaging microscopy has traditionally been used because of the high specificity that is achievable through fluorescence labeling techniques and optical filtering. When combined with spectral imaging technologies, fluorescence microscopy can allow for quantitative identification of multiple fluorescent labels. We are working to develop a new approach for spectral imaging that samples the fluorescence excitation spectrum and may provide increased signal strength.

View Article and Find Full Text PDF