Glaucoma is a progressive optic neuropathy that is the second leading cause of preventable blindness worldwide, after cataract formation. A rise in the intraocular pressure (IOP) is considered to be a major risk factor for glaucoma and is associated with an abnormal increase of resistance to aqueous humour outflow from the anterior chamber. Glaucoma drainage devices have been developed to provide an alternative pathway through which aqueous humour can effectively exit the anterior chamber, thereby reducing IOP. These devices include the traditional aqueous shunts with tube-plate design, as well as more recent implants, such as the trabeculectomy-modifying EX-PRESS implant and the new minimally invasive glaucoma surgery (MIGS) devices. In this review, we will describe each implant in detail, focusing on their efficacy in reducing IOP and safety profile. Additionally, a critical and evidence-based comparison between these implants will be provided. Finally, we will propose potential developments that may help to improve the performance of current devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8602385PMC
http://dx.doi.org/10.1038/s41433-021-01595-xDOI Listing

Publication Analysis

Top Keywords

migs devices
8
aqueous humour
8
anterior chamber
8
reducing iop
8
devices
5
conventional glaucoma
4
glaucoma implants
4
implants migs
4
devices comprehensive
4
comprehensive review
4

Similar Publications

First-Principles Assessment of ZnTe and CdSe as Prospective Tunnel Barriers at the InAs/Al Interface.

ACS Appl Mater Interfaces

January 2025

Department of Materials Science and Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213, United States.

Majorana zero modes are predicted to emerge in semiconductor/superconductor interfaces, such as InAs/Al. Majorana modes could be utilized for fault tolerant topological qubits. However, their realization is hindered by materials challenges.

View Article and Find Full Text PDF

Xen 63 versus Preserflo MicroShunt implant in patients with primary open-angle glaucoma.

Sci Rep

January 2025

Department of Ophthalmology and ORL, Faculty of Medicine, Clinico San Carlos Hospital, Complutense University, Clinico San Carlos Hospital Health Research Institute (IdISSC), Calle del Prof Martín Lagos, s/n,, Madrid, 28040, Spain.

This study compared the efficacy safety profiles of the Xen 63 and Preserflo MicroShunt devices, both standalone, in patients with primary open-angle glaucoma (POAG). It is a retrospective and single-center study conducted on consecutive on patients with medically uncontrolled POAG who underwent either a standalone Xen 63 or a standalone Preserflo and had a 12-month follow-up visit. The primary outcome was the mean IOP at month-12.

View Article and Find Full Text PDF

Anticoagulation for Minimally Invasive Glaucoma Surgery: An American Glaucoma Society Survey.

J Glaucoma

November 2024

The Scheie Eye Institute, Department of Ophthalmology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.

Precis: Perspectives and practice patterns regarding perioperative anticoagulation management and minimally invasive glaucoma surgery were queried among surgeons of American Glaucoma Society. Management varied based on surgeon preference and type of procedure performed.

Purpose: The purpose of this study was to characterize anticoagulation and antiplatelet practice patterns for minimally invasive glaucoma surgery (MIGS) in the perioperative period.

View Article and Find Full Text PDF

Is minimally invasive glaucoma surgery killing trabeculectomies?

Curr Opin Ophthalmol

November 2024

Centre for Vision Research, Westmead Institute for Medical Research, University of Sydney.

Purpose Of Review: The introduction of minimally invasive glaucoma surgery (MIGS) has changed the surgical landscape of glaucoma surgery. For more than four decades, the most commonly performed glaucoma surgery around the world has been the trabeculectomy. This article examines whether trabeculectomy is still the predominant procedure in glaucoma today, in the context of rapidly emerging MIGS devices and procedures.

View Article and Find Full Text PDF

Purpose: To evaluate the incidence and to describe the characteristics of the intrableb pigmentation (IBP) following XEN63 implantation.

Methods: Retrospective case series of three eyes presenting a pigment dispersion in the filtering bleb after a XEN63 implantation for uncontrolled IOP. Demographic, clinical and imaging data were obtained from medical records.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!