This work explores the distribution of time intervals between signals from the photomultiplier tubes (PMTs) of a liquid scintillation counting (LSC) system when a scintillation burst caused by an ionizing particle is detected. This distribution is termed the cross-correlation distribution and it is shown that it contains information about the probability to detect a scintillation event. A theoretical model that describes the cross-correlation distribution is derived. The model can be used to estimate the mean number of detected photons in a LSC measurement, which allows the calculation of the detection efficiency. The theoretical findings are validated by Monte Carlo simulations and by experiments with low-energy beta-emitting and electron-capture radionuclides ([Formula: see text], [Formula: see text], [Formula: see text] and [Formula: see text]), with dedicated LSC systems and several commercial LSC cocktails. The results show that some of the parameters of the cross-correlation distribution such as the peak height or the kurtosis can be used as detection efficiency estimators or quenching indicators in LSC. Thus, although the time domain and the cross-correlation distribution have received little to no attention in the practice of LSC, they have the capacity to bring significant improvements in almost all LSC applications related to activity determination of low-energy beta-emitting and electron-capture radionuclides. The results also suggest concepts for the development of innovative LSC systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8203662 | PMC |
http://dx.doi.org/10.1038/s41598-021-91873-1 | DOI Listing |
PLoS One
January 2025
Department of Finance, Zhejiang University of Finance and Economics, Hangzhou, China.
This study explores the intricate dynamics of volatility within high-frequency financial markets, focusing on 225 of Chinese listed companies from 2016 to 2023. Utilizing 5-minute high-frequency data, we analyze the realized volatility of individual stocks across six distinct time scales: 5-minute, 10-minute, 30-minute, 1-hour, 2-hour, and 4-hour intervals. Our investigation reveals a consistent power law decay in the auto-correlation function of realized volatility across all time scales.
View Article and Find Full Text PDFIn addition to laser frequency sweep nonlinearity, sensing point misalignment caused by a random laser frequency sweep range (LFSR) is a key factor limiting the sensing performance of the optical frequency domain reflectometer (OFDR). Here we propose a synchronous equal frequency resampling (SEFR) method for the first time to our knowledge to simultaneously compensate both the random LFSR and sweep nonlinearity. A new linear frequency sequence has been constructed to perform signal resampling of both the reference and measurement stages, which eliminates the sensing point misalignment and nonlinear frequency interval at the same time.
View Article and Find Full Text PDFCell Biochem Biophys
December 2024
Department of Biophysics and Pharmacology, Federal University of Rio Grande do Norte, Natal/RN, Brazil.
Life (Basel)
November 2024
School of Sport Science, Beijing Sport University, Beijing 100084, China.
In forehand strokes with different grips in tennis, the forearm muscle activities, the distribution and attenuation of the impact loads, and the effects of the muscles on the impact load attenuation exhibited different characteristics. This study aimed to explore these characteristics by analyzing electromyography (EMG) and acceleration data, and comparing the differences between the Eastern and Western grips. Fourteen level II or above tennis players (ten males, aged 22.
View Article and Find Full Text PDFbioRxiv
November 2024
Regeneron Pharmaceuticals, Tarrytown NY.
The auditory brainstem response (ABR) is an essential diagnostic indicator of overall cochlear health, used extensively in both basic research and clinical studies. A key quantification of the ABR is threshold, the lowest sound level that elicits a response. Because the morphology of ABR waveforms shift with stimulus level and the overall signal-to-noise ratio is low, threshold estimation is not straightforward.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!