Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Mad honey intoxication (MHI) is a food-induced clinical condition that usually presents with cardiovascular symptoms and can lead to life-threatening arrhythmias if not diagnosed and treated early. No data exist in the literature on the presence of interatrial block (IAB) after food intoxication. In our study, we sought to investigate atrioventricular electrocardiography (ECG) parameters and determine the frequency of IAB in patients with MHI. In total, 76 patients diagnosed with MHI were included in our retrospective study. Twelve-lead ECGs were performed and participants were divided into two groups according to the presence of IAB in the reference ECG. The P maximum (P), P minimum (P), P dispersion (P), T peak to T end (Tp-Te) interval and QT dispersion (QT) values were compared between the two groups. IAB was detected in 28 (35.5%) of 76 MHI patients included in the final analysis. P duration (122 ± 8; p < 0.001) and PD (69 ± 11; p < 0.001) were significantly higher in the IAB ( +) group. During regression analysis, P [odds ratio (OR) 1.158, 95% confidence interval (CI) 1.036-1.294; p = 0.010] and Pd (OR 1.086, 95% CI 1.001-1.017; p = 0.046) were independently associated with IAB. P and Pd area under the receiver operating characteristic curve values for IAB prediction were 0.926 (95% CI 0.841-1,000; p < 0.001) and 0.872 (95% CI 0.765-0.974; p < 0.001), respectively. ECG changes are common in patients presenting with MHI. These patients need to be followed up clinically in terms of progression to arrhythmic events that may occur in the future.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12012-021-09668-9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!