Purpose: The aims of the present study were to compare the biomechanical properties of tibial fixation in hamstring-graft ACL reconstruction using interference screw and a novel combination interference screw and dowel construct.

Material And Methods: We compared the fixation of 30 (2- and 4-stranded gracilis and semitendinosis tendons) in 15 fresh-frozen porcine tibiae with a biocomposite resorbable interference screw (Group 1) and a screw and dowel construct (Group 2). Each graft was subjected to load-to-failure testing (50 mm/min) to determine maximum load, displacement at failure and pullout strength.

Results: There were no significant differences between the biomechanical properties of the constructs. Multivariate analysis demonstrated that combination constructs (β = 140.20, p = 0.043), screw diameter (β = 185, p = 0.006) and 4-strand grafts (β = 51, p = 0.050) were associated with a significant increase in load at failure. Larger screw diameter was associated with increased construct stiffness (β = 20.15, p = 0.020).

Conclusion: The screw and dowel construct led to significantly increased fixation properties compared to interference screws alone in a porcine model. Increased screw diameter and utilization of 4-strand ACL grafts also led to improvement in load-to-failure of the construct. However, this is an in vitro study and additional investigations are needed to determine whether the results are reproducible in vivo.

Level Of Evidence: Level V; Biomechanical study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-021-03049-2DOI Listing

Publication Analysis

Top Keywords

screw dowel
16
dowel construct
12
interference screw
12
screw diameter
12
tibial fixation
8
biomechanical properties
8
screw
8
construct
5
combined screw
4
dowel
4

Similar Publications

Board furniture's performance and scientific design are making it popular. Research on simplifying furniture joints reduces design cycles and costs and improves structural safety. In this article, using a cantilever beam to calculate deflection theoretically simplifies the L-shaped component model and yields a joint elastic modulus formula.

View Article and Find Full Text PDF

Energy Consumption for Furniture Joints during Drilling in Birch Plywood.

Polymers (Basel)

April 2024

Department of Furniture Design, Faculty of Forestry and Wood Technology, Poznań University of Life Sciences, ul. Wojska Polskiego 38/42, 60-627 Poznan, Poland.

The purpose of this study is to support eco-design ideas and sustainable manufacturing techniques by examining the energy consumption related to drilling holes for different furniture connections. The experimental model is a simple piece of furniture made from birch plywood with three different types of joints. Eccentric joints, confirmat screws, and dowel measurements of energy consumption with a CNC drilling and milling machine show different values for every kind of connector.

View Article and Find Full Text PDF

Objective: This is a single-surgeon series that prospectively evaluates the results of sacroiliac joint (SIJ) fusion for patients with SIJ dysfunction using hydroxyapatite-coated screws (HACSs) compared with titanium triangular dowels (TTDs).

Methods: A total of 113 patients underwent SIJ fusion surgery between 2013 and 2018 at the University Hospital Llandough to treat symptomatic SIJ dysfunction not responding to nonoperative measures. Of the 113 patients, 40 were treated with HACSs and 73 with TTDs.

View Article and Find Full Text PDF

The corticocancellous press fit iliac crest bone dowel for recalcitrant scaphoid nonunion: analysis of union rate and clinical outcome.

Arch Orthop Trauma Surg

September 2023

Department of Hand, Plastic, Reconstructive and Burn Surgery, BG Unfallklinik Tübingen, Eberhard Karls University Tuebingen, Schnarrenbergstr. 95, 72076, Tuebingen, Germany.

Introduction: Scaphoid nonunion after failed primary treatment remains challenging particularly when entailed by bone loss, avascular necrosis or deformity. We describe a scaphoid augmentation and fixation technique for cases of recalcitrant nonunion after screw placement by autologous press fit corticocancellous dowel. This study aims to provide reliable data on clinical and radiological outcomes and to contextualize in the face of other treatment options.

View Article and Find Full Text PDF

Renal insufficiency is a risk factor for osteoporosis and can increase risk of fracture. It may be a result of an age-related decline in renal function or chronic kidney disease. In patients with CKD, accurate diagnosis of osteoporosis or CKD-MBD is important for determining the most appropriate treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!