Objectives: The aim of this study was to evaluate the shaping ability of the TruShape and Reciproc Blue systems and the apical extrusion of debris after root canal instrumentation. The ProTaper Universal system was used as a reference for comparison.
Materials And Methods: Thirty-three mandibular premolars with a single canal were scanned using micro-computed tomography and were matched into 3 groups ( = 11) according to the instrumentation system: TruShape, Reciproc Blue and ProTaper Universal. The teeth were accessed and mounted in an apparatus with agarose gel, which simulated apical resistance provided by the periapical tissue and enabled the collection of apically extruded debris. During root canal preparation, 2.5% sodium hypochlorite was used as an irrigant. The samples were scanned again after instrumentation. The percentage of unprepared area, removed dentin, and volume of apically extruded debris were analyzed. The data were analyzed using 1-way analysis of variance and the Tukey test for multiple comparisons at a 5% significance level.
Results: No significant differences in the percentage of unprepared area were observed among the systems ( > 0.05). ProTaper Universal presented a higher percentage of dentin removal than the TruShape and Reciproc Blue systems ( < 0.05). The systems produced similar volumes of apically extruded debris ( > 0.05).
Conclusions: All systems caused apically extruded debris, without any significant differences among them. TruShape, Reciproc Blue, and ProTaper Universal presented similar percentages of unprepared area after root canal instrumentation; however, ProTaper Universal was associated with higher dentin removal than the other systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170380 | PMC |
http://dx.doi.org/10.5395/rde.2021.46.e16 | DOI Listing |
J Endod
December 2024
Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan; National Taiwan University Hospital, National Taiwan University, Taipei City, Taiwan; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung City, Taiwan. Electronic address:
Introduction: The separation of Nickel-Titanium (NiTi) endodontic instruments due to excessive torque adversely affects treatment outcomes. Previous studies have analyzed torque values under static conditions and failed to accurately simulate the dynamic conditions of instruments within root canals. This study aimed to apply a novel finite element analysis (FEA) to assess the real-time dynamic performance of NiTi endodontic instruments during operation in root canals.
View Article and Find Full Text PDFDent J (Basel)
November 2024
Department of General Surgery and Surgical-Medical Specialties, University of Catania, 95131 Catania, Italy.
: Apical extrusion of debris can affect the success of endodontic treatments, and the specific performance of certain retreatment systems has not been studied yet. Therefore, the aim of this in vitro study was to quantitatively assess the amount of apically extruded debris produced during retreatment procedures using three rotary NiTi retreatment systems in mature non-resorbed straight roots. : Thirty extracted permanent human teeth with single straight roots were selected.
View Article and Find Full Text PDFJ Dent (Shiraz)
December 2024
Dept. of Pediatric and Preventive Dentistry, Terna Dental College, Phase - II, Sector- 22, Nerul (west), Navi Mumbai, India.
Statement Of The Problem: Root canal preparation with rotary files causes dentinal cracks in root canals of primary teeth affecting their longevity.
Purpose: Nickel-titanium rotary files have been widely used for root canal preparation in primary teeth. The present study compared occurrence of dentinal microcracks in root canals of extracted primary molar teeth prepared using Hedstrom (H) files, ProTaper Universal rotary files, and ProTaper Next rotary file systems.
Eur Endod J
December 2024
Department of Conservative Dentistry and Endodontics, University of Jammu, J and K, Indira Gandhi Government Dental College Jammu, India.
Objective: The present study aimed to evaluate the effect of heat-treated nickel titanium (NiTi) files TruNatomy and XP- Endo Shaper on the major apical foramen deformation and enlargement in curved root canals using area, circularity, and Feret's diameter ratio.
Methods: Sixty mesio-buccal roots of maxillary and mandibular molars with Vertucci type II root canal were selected. The teeth were decoronated using a carborundum disc.
Front Bioeng Biotechnol
December 2024
Department of Cariology and Endodontology, Qingdao Stomatological Hospital Affiliated to Qingdao University, Qingdao, Shandong, China.
Objective: To compare the effect of syringe irrigation technique, passive ultrasonic activation technique, EDDY activation technique and Er,Cr,YSGG laser activation technique on smear layer removal in root canals .
Methods: Forty mandibular first premolars with single canal were collected from patients in Qingdao Stomatological Hospital affiliated to Qingdao University. After root canal preparation with ProTaper Universal to F3, they were randomly divided into four groups (n = 10) according to different activation irrigations for the final washing: syringe irrigation (SI), passive ultrasonic activation (PU), EDDY activation (EDDY) and Er,Cr,YSGG laser activation (YSGG).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!