Adverse events in total hip replacement (THR) may have several origins, one being lack of precision in diagnosis and/or during surgery. This study describes the pattern and frequency of avoidable injuries in THR and the potential value of a new tool for early diagnosis of implant loosening. This retrospective study was based on all ( = 1 456) settled claims regarding THR in the Swedish National Patient Insurance database from 2010 to 2017. The claims and medical records were analyzed for root causes, with special focus on adverse events where lack of precision could be the cause. In a second stage, we assessed in 10 patients (20 implants) the diagnostic precision of a new software tool based on provocation-CT. These were all patients where the implant loosening diagnosis was deemed as inconclusive after a first plain X-ray. The findings from the provocation-CT and plain X-ray were compared to the surgical findings at revision. While 3 of 20 implants were correctly diagnosed with plain X-ray, for dynamic CT, this number was 14 of 20 implants. The retrospective study showed that the most common types of injuries were infections (34%), nerve injury (29%), mechanical problems (14.5%), dislocation (6%), and miscellaneous complications (16.5%). Of the patients with mechanical complications, one-third had aseptic implant loosening. Statement of clinical significance: we estimated that almost 200 patients in our registry study had mechanical complications after THR, mainly implant loosening. A third of these could potentially have been diagnosed and treated if CT examination with a dedicated image analysis tool to assess implant loosening after THR had been available.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8192178 | PMC |
http://dx.doi.org/10.1155/2021/8836687 | DOI Listing |
Int J Oral Maxillofac Implants
January 2025
Purpose: This retrospective clinical study aims to analyze single-unit implant-supported restorations' clinical and radiographic outcomes comprehensively.
Materials And Methods: In this retrospective study, patients who had undergone 12 months of implant-supported singleunit fixed prosthetic treatment were scanned from the archives, and a hundred patients were included in the study. Implant success and survival rates were assessed according to the consensus decisions published at the International Oral Implantology Congress in 2007.
Clin Implant Dent Relat Res
February 2025
Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.
Introduction: Implantology has become a primary solution for tooth loss due to excellent osseointegration and high long-term success rates. However, complications such as abutment screw loosening, especially in implant-supported single crowns, compromise prosthesis longevity. Anaerobic adhesives (AAs) have shown promise in mechanical fields for preventing screw loosening, but their effectiveness in dental implants, particularly zirconia, remains uncertain.
View Article and Find Full Text PDFArthroplast Today
December 2024
The CORE Institute, Phoenix, AZ, USA.
Background: Arthroplasty registries play a critical role in improving the quality of care and performing post-market surveillance of medical devices. We report the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) findings specific to the Biomet Vanguard XP bicruciate-retaining total knee implant.
Methods: Data were collected from MARCQI's 2019 report (February 15, 2012, through December 31, 2018).
JSES Int
November 2024
Division of Hand and Upper-Extremity Surgery, Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger MSKI, Danville, PA, USA.
Background: Revision total elbow arthroplasty (rTEA) remains a technically challenging procedure with potential for substantial morbidity. Cases involving excessively long cement mantles, removal of well-fixed implants or infected revisions requiring complete cement removal introduce additional technical challenges. Our purpose was to describe the outcomes, results, and complications associated with the use of cortical windows in rTEA.
View Article and Find Full Text PDFJSES Int
November 2024
Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden.
Background: The humeral head resurfacing arthroplasty (HHR) is normally used as a hemi shoulder arthroplasty and has been in use for the treatment of Gleno-Humeral osteoarthritis (OA) of the shoulder for more than 30 years. Some studies, however, shows that anatomical total shoulder arthroplasty provides better improvement in function than a HHR for patients with OA. Reasons for this may be a progressive glenoid wear (GW) or loosening of the HHR.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!