Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Electroencephalogram (EEG) is used in the neurological prognostication after cardiac arrest. "Highly malignant" EEG patterns classified according to Westhall have a high specificity for poor neurological outcome when applied within protocols of recent studies. However, their predictive performance when applied in everyday clinical practice has not been investigated. We studied the prognostic accuracy and the interrater agreement when standardized EEG patterns were analysed and compared to neurological outcome in a patient cohort at a tertiary centre not involved in the original study of the standardized EEG pattern classification.
Methods: Comatose patients treated for out-of-hospital cardiac arrest were included. Poor outcome was defined as Cerebral Performance Category 3-5. Two senior consultants and one resident in clinical neurophysiology, blinded to clinical data and outcome, independently reviewed their EEG registrations and categorised the pattern as "highly malignant", "malignant" or "benign". These categories were compared to neurological outcome at hospital discharge. Interrater agreement was assessed using Cohen's Kappa.
Results: In total, 62 patients were included. The median (IQR) time to EEG was 59 (42-91) h after return of spontaneous circulation. Poor outcome was found in 52 (84%) patients. In 21 patients at least one of the raters considered the EEG to contain a "highly malignant" pattern, all with poor outcome (42% sensitivity, 100% specificity). The interrater agreement varied from kappa 0.62 to 0.29.
Conclusion: "Highly malignant" patterns predict poor neurological outcome with a high specificity in everyday practice. However, interrater agreement may vary substantially even between experienced EEG interpreters.