A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application of a standardized EEG pattern classification in the assessment of neurological prognosis after cardiac arrest: A retrospective analysis. | LitMetric

Application of a standardized EEG pattern classification in the assessment of neurological prognosis after cardiac arrest: A retrospective analysis.

Resuscitation

Department of Anaesthesiology and Intensive Care Medicine, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

Published: August 2021

Introduction: Electroencephalogram (EEG) is used in the neurological prognostication after cardiac arrest. "Highly malignant" EEG patterns classified according to Westhall have a high specificity for poor neurological outcome when applied within protocols of recent studies. However, their predictive performance when applied in everyday clinical practice has not been investigated. We studied the prognostic accuracy and the interrater agreement when standardized EEG patterns were analysed and compared to neurological outcome in a patient cohort at a tertiary centre not involved in the original study of the standardized EEG pattern classification.

Methods: Comatose patients treated for out-of-hospital cardiac arrest were included. Poor outcome was defined as Cerebral Performance Category 3-5. Two senior consultants and one resident in clinical neurophysiology, blinded to clinical data and outcome, independently reviewed their EEG registrations and categorised the pattern as "highly malignant", "malignant" or "benign". These categories were compared to neurological outcome at hospital discharge. Interrater agreement was assessed using Cohen's Kappa.

Results: In total, 62 patients were included. The median (IQR) time to EEG was 59 (42-91) h after return of spontaneous circulation. Poor outcome was found in 52 (84%) patients. In 21 patients at least one of the raters considered the EEG to contain a "highly malignant" pattern, all with poor outcome (42% sensitivity, 100% specificity). The interrater agreement varied from kappa 0.62 to 0.29.

Conclusion: "Highly malignant" patterns predict poor neurological outcome with a high specificity in everyday practice. However, interrater agreement may vary substantially even between experienced EEG interpreters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resuscitation.2021.05.037DOI Listing

Publication Analysis

Top Keywords

"highly malignant"
16
neurological outcome
16
interrater agreement
16
standardized eeg
12
cardiac arrest
12
poor outcome
12
eeg
9
eeg pattern
8
eeg patterns
8
high specificity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!