Clinical outcomes and safety of the SpineJack vertebral augmentation system for the treatment of vertebral compression fractures in a United States patient population.

J Clin Neurosci

Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins Hospital, 1800 Orleans Street, Baltimore, MD 21287, United States; Department of Radiology, Thomas Jefferson University Hospital, 111 S 11(th) St, Philadelphia, PA 19107, United States.

Published: July 2021

The SpineJack implant system was recently FDA approved for treatment of vertebral compression fractures (VCF), however United States-based outcomes data is lacking. We sought to examine the safety and clinical outcomes following vertebral augmentation using the SpineJack implant for treatment of VCF in a U.S. patient population. An IRB-approved, retrospective study of SpineJack implants used in vertebral augmentation was performed from 11/2018 to 2/2020. Outcome objectives included pain improvement, vertebral body height (VH) restoration, improvement in local kyphotic angle (LKA), and incidence of adjacent level fractures (ALF). Complications were reviewed to assess safety of the procedure. Thirty patients with VCF (60% female; mean [SD] age of 62.7 [±12.8] years) underwent a total of 53 vertebral augmentations with 106 SpineJack implants. Worst pain scores decreased significantly from 8.7 to 4.3 (95%CI of the change [Δ]: 4.3-4.4; p < 0.001). Middle and anterior VH significantly increased from 13.1 ± 0.2 to 15.9 ± 0.2 mm (95%CI Δ: 2.6-2.9 mm; p < 0.001) and 15.6 ± 0.2 to 16.8 ± 0.2 mm (95%CI Δ: 1.1-1.4 mm; p < 0.001), respectively. LKA was significantly decreased from 10.0 ± 2.1 to 7.4 ± 2.1 degrees (95%CI Δ: 2.4-2.8 degrees; p < 0.001). Four patients (13%) sustained ten ALF over a median (IQR) follow up period of 94 (17.5-203) days. There were no major adverse events during the follow up period. To summarize, vertebral augmentation with SpineJack implants of patients with VCF resulted in significantly decreased pain, restored VH, and improved LKA, without major adverse events. However, 13% of patients sustained ALF during a median follow up period of 3 months.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2021.04.031DOI Listing

Publication Analysis

Top Keywords

vertebral augmentation
12
clinical outcomes
8
treatment vertebral
8
vertebral compression
8
compression fractures
8
patient population
8
spinejack implant
8
spinejack implants
8
vertebral
7
spinejack
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!