Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Total organic carbon (TOC) is an important parameter describing organic pollution degree of waters. Due to the increasing need of field analysis and drawbacks of conventional TOC analytical instruments, miniaturized TOC analyzers are still demanding. In this work, a dielectric barrier discharge (DBD) microplasma was utilized for catalytic oxidation vapor generation (COVG) of organic compounds into CO, and a point discharge (PD) microplasma was employed to excite the carbon atomic emission spectra for quantification. Sample solution with phosphoric acid and persulfate solution was injected into the DBD-COVG reactor by a syringe to convert organic compounds into CO efficiently and quickly, which was subsequently transported into the point discharge optical emission spectrometer (PD-OES) for detecting carbon at 193.09 nm. Under optimal experimental conditions, high oxidation efficiencies for several organic compounds were achieved, i.e., 96.4%, 95.1% and 94.3% for 50 mg L potassium hydrogen phthalate (KHP), sodium laurylsulfonate and phenol, respectively. A limit of detection (LOD) of 0.02 mg L (as C) was obtained, with a precision of 3.9% (relative standard deviation, RSD) at 15 mg L TOC standard (as C). The possible catalytic oxidation mechanism was proposed with the characteristic results of electron paramagnetic resonance (EPR). Its potential environmental application was demonstrated by successfully analyzing TOC in underground water, surface river water and surface sedimentary water samples from oil fields, with analytical results agreed well with those obtained by the commercial high-temperature combustion coupled nondispersive infrared absorption (HTC-NDIR) technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2021.338683 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!