Periodontological grafts are materials used in dentistry to regenerate lost gingival soft tissues or bone parts. In the case of direct contact with blood, the possibility of disease transmission from the source to the patient is high. This source can be an animal or a human. Therefore, the sterilization of grafts before implanting to the patient is of significant importance. The purpose of this study was to evaluate gamma radiation and microwave sterilization processes from microbiological and sterility perspectives and to compare the effectiveness of these two sterilization methods. Grafts were irradiated with 2, 4, 5, 10, 25 and 50 kGy doses of gamma radiation. Another group of same materials was irradiated by microwave for 1, 2, 3 and 4 min at 24,500 MHz and 900 W. Gamma radiation and microwave sterilization methods were evaluated as successful at minimum doses as 5 kGy and 3 min, respectively. Both gamma and microwave sterilization successfu lly sterilized periodontological grafts coded as PBG1, HBG1, HL1, PDG1, MBG3, MDG2 and PDG3. Moreover, microwave sterilization can be used as an alternative novel method to gamma radiation sterilization.

Download full-text PDF

Source
http://dx.doi.org/10.1111/apm.13162DOI Listing

Publication Analysis

Top Keywords

gamma radiation
16
microwave sterilization
16
periodontological grafts
12
gamma microwave
8
sterilization
8
radiation sterilization
8
radiation microwave
8
sterilization methods
8
gamma
6
radiation
5

Similar Publications

Background: Even a gross total resection of a benign epidermoid tumor (ET) carries a high risk of recurrence. The management strategy mostly involves redo surgical excision but at a significant cost of morbidity and mortality. The role of adjuvant radiation therapies in this scenario is still undefined.

View Article and Find Full Text PDF

Pancreatic ductal adenocarcinoma (PDAC) is notably resistant to conventional chemotherapy and radiation treatment. However, clinical trials indicate that carbon ion radiotherapy (CIRT) with concurrent gemcitabine is effective for unresectable locally advanced PDAC. This study aimed to identify patient characteristics predictive of CIRT response.

View Article and Find Full Text PDF

Background: Tremor, either in patients with Essential Tremor (ET) or Parkinson's disease (PD), constitutes the most common movement disorder. Stereotactic radiosurgery using Gamma Knife (GK) and linear accelerator (LINAC) systems, is an effective, incisionless treatment modality for ET and PD. Although these technologies have been used clinically since the 1990's, most studies have focused on GK, and efficacy, safety and time to treatment effect (latency) of GK and LINAC have not been compared.

View Article and Find Full Text PDF

Multi-layer shielding optimization of a high activity Am-Be mixed field irradiation facility.

Appl Radiat Isot

January 2025

Experimental Nuclear Physics Department, Nuclear Research Centre, Egyptian Atomic Energy Authority, Egypt; Cyclotron Facility, Egyptian Atomic Energy Authority, Egypt.

Neutron and gamma-ray shielding design for a 30Ci (1.11TBq) Am-Be irradiation facility is studied using MCNP5 Monte Carlo simulation code. The study focuses on the optimization of the shielding layers of the previously planned neutron irradiation facility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!