Objectives: To determine whether single-phase dual-energy CT (DECT) differentiates vascular and nonvascular renal lesions in the portal venous phase (PVP). Optimal iodine threshold was determined and compared to Hounsfield unit (HU) measurements.

Methods: We retrospectively included 250 patients (266 renal lesions) who underwent a clinically indicated PVP abdominopelvic CT on a rapid-kilovoltage-switching single-source DECT (rsDECT) or a dual-source DECT (dsDECT) scanner. Iodine concentration and HU measurements were calculated by four experienced readers. Diagnostic accuracy was determined using biopsy results and follow-up imaging as reference standard. Area under the curve (AUC) was calculated for each DECT scanner to differentiate vascular from nonvascular lesions and vascular lesions from hemorrhagic/proteinaceous cysts. Univariable and multivariable logistic regression analyses evaluated the association between variables and the presence of vascular lesions.

Results: A normalized iodine concentration threshold of 0.25 mg/mL yielded high accuracy in differentiating vascular and nonvascular lesions (AUC 0.93, p < 0.001), with comparable performance to HU measurements (AUC 0.93). Both iodine concentration and HU measurements were independently associated with vascular lesions when adjusted for age, gender, body mass index, and lesion size (AUC 0.95 and 0.95, respectively). When combined, diagnostic performance was higher (AUC 0.96). Both absolute and normalized iodine concentrations performed better than HU measurements (AUC 0.92 vs. AUC 0.87) in differentiating vascular lesions from hemorrhagic/proteinaceous cysts.

Conclusion: A single-phase (PVP) DECT scan yields high accuracy to differentiate vascular from nonvascular renal lesions. Iodine concentration showed a slightly higher performance than HU measurements in differentiating vascular lesions from hemorrhagic/proteinaceous cysts.

Key Points: • A single-phase dual-energy CT scan in the portal venous phase differentiates vascular from nonvascular renal lesions with high accuracy (AUC 0.93). • When combined, iodine concentration and HU measurements showed the highest diagnostic performance (AUC 0.96) to differentiate vascular from nonvascular renal lesions. • Compared to HU measurements, iodine concentration showed a slightly higher performance in differentiating vascular lesions from hemorrhagic/proteinaceous cysts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9282667PMC
http://dx.doi.org/10.1007/s00330-021-08097-0DOI Listing

Publication Analysis

Top Keywords

vascular nonvascular
28
renal lesions
24
iodine concentration
24
vascular lesions
20
differentiate vascular
16
nonvascular renal
16
lesions hemorrhagic/proteinaceous
16
differentiating vascular
16
vascular
13
lesions
13

Similar Publications

Feasibility of Ex Vivo Ligandomics.

Biomolecules

January 2025

Cullen Eye Institute, Department of Ophthalmology, Baylor College of Medicine, Houston, TX 77030, USA.

We developed ligandomics for the in vivo profiling of vascular ligands in mice, discovering secretogranin III (Scg3) as a novel angiogenic factor that selectively binds to retinal vessels of diabetic but not healthy mice. This discovery led to the development of anti-Scg3 therapy for ocular vasculopathies. However, in vivo ligandomics requires intracardial perfusion to remove unbound phage clones, limiting its use to vascular endothelial cells (ECs).

View Article and Find Full Text PDF

Purpose: To report the occurrence of acute postrenal kidney failure caused by external ureteral obstruction after iliac venous stent placement.

Case Report: A 73-year-old male patient presented with a chronic swelling and feeling of heaviness of his right leg. The presence of venous thrombosis was excluded by duplex ultrasound (DUS).

View Article and Find Full Text PDF

Purpose: Bangladesh has experienced a rapid epidemiological transition from communicable to non-communicable diseases (NCDs) in recent decades. There is, however, limited evidence about multidimensional determinants of NCDs in this population. The BangladEsh Longitudinal Investigation of Emerging Vascular and nonvascular Events (BELIEVE) study is a household-based prospective cohort study established to investigate biological, behavioural, environmental and broader determinants of NCDs.

View Article and Find Full Text PDF

Introduction: Bryophytes are non-vascular plants that appeared on Earth before vascular plants. More than 24,000 species are reported worldwide, and only a small proportion have been studied. However, part of their biosynthetic potential has been unveiled and more than 1,600 terpenoids have been detected and identified.

View Article and Find Full Text PDF

To explore techniques, advantages and disadvantages of 3D Slicer reconstruction and 3D printing localization technology combined with transcranial neuroendoscopy in ventriculoperitoneal shunt surgery. Retrospective analysis of clinical data of patients with hydrocephalus treated by ventriculoperitoneal shunt surgery using 3D Slicer reconstruction and 3D printing positioning technology combined with transcranial neuroendoscopy in our hospital from October 2021 to March 2023. A total of 33 patients with complete data were collected, including 19 males and 14 females, aged 10-81 years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!