Results of shoulder abduction reconstruction in partial upper-type brachial plexus avulsion injuries are better when a triceps nerve is transferred to the axillary nerve in addition to the spinal accessory to suprascapular nerve transfer. However, in C5-7 avulsion injuries, the triceps nerve may be unavailable as a donor nerve. We report the results of an alternative neurotization to the axillary nerve using either a partial median or ulnar nerve. Patients with C5, 6 ± 7 avulsion injuries and weak triceps who underwent dual nerve transfers for shoulder abduction reconstruction were recruited for the study. The second neurotization to the axillary nerve was from either a partial median or ulnar nerve that had an expandable muscle innervation of ≥ M4 motor power. Patients were assessed for recovery of shoulder abduction and external rotation. Nine patients (median age = 23 years) underwent these dual neurotizations from March 2005 to April 2013. The median time to surgery was 4.5 months. Recovery of shoulder abduction averaged 114.4° (range 90°-180°) and external rotation averaged 136.3° (range 135°-140°). Final shoulder abduction power was > M3 in all 9 patients and ≥ M4 in 6 patients. One patient with partial median nerve transfer had transient hypoaesthesia in his thumb and index finger and another had a residual M4 power in his thumb and index finger flexors. In C5-7 avulsion injuries, dual nerve transfers of the spinal accessory to suprascapular nerve and partial median or ulnar nerve to axillary nerve are good options for shoulder abduction reconstruction with minimal morbidity. Level of evidence is level IV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/2000656X.2021.1934842 | DOI Listing |
J Clin Med
January 2025
Division of Shoulder Sports Medicine and Arthroplasty, Department of Orthopedic Surgery, Jeju National University Hospital, Jeju 63241, Republic of Korea.
To evaluate the clinical and radiologic outcomes of arthroscopic augmented partial repair (APR) with acellular dermal matrix versus arthroscopic superior capsular reconstruction (SCR) in massive rotator cuff tears. The study included a total of 49 patients with massive rotator cuff tears who underwent arthroscopic APR (26 patients) and SCR (23 patients) between March 2018 and June 2021. Clinical scores, visual analog scores, and range of motion were collected preoperatively and postoperatively until the last follow-up.
View Article and Find Full Text PDFHealthcare (Basel)
December 2024
Interlevel Clinical Management Unit of Physical Medicine and Rehabilitation, Reina Sofía University Hospital, Córdoba and Guadalquivir Health District, 14011 Córdoba, Spain.
: Shoulder pain is a very common health issue among adults, being 8% due to calcifying tendinopathies (CT) of the shoulder. The evolutionary process of this lesion can be classified according to Bianchi Martinoli, depending on the ultrasound appearance. In 50% of cases, with first-line treatments, they resolve spontaneously.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505 South Korea.
Unlabelled: Accurate assessment of shoulder range of motion (ROM) is crucial for evaluating patient progress. Traditional manual goniometry often lacks precision and is subject to inter-observer variability, especially in measuring shoulder internal rotation (IR). This study introduces an artificial intelligence (AI)-based approach that uses clinical photography to improve the accuracy of ROM quantification.
View Article and Find Full Text PDFCurr Rev Musculoskelet Med
January 2025
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
Purpose Of Review: With the growing popularity and broadening indications for Reverse Shoulder Arthroplasty (RSA), increasing modularity in design and adjustments to each component can enhance postoperative range of motion (ROM), thus expanding treatment capabilities. This review outlines the advancements developed to optimize ROM through modifications in glenoid and humeral components and the integration of computational tools for surgical planning.
Recent Findings: Enhancements in glenoid component design aim to mitigate complications like scapular notching and improve ROM, particularly in abduction and external rotation.
Arthroscopy
January 2025
Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA USA. Electronic address:
In terms of rotator cuff repair, there is a goal for complete repair and healing, as rotator cuff integrity correlates with clinical and functional results. Retear has been shown to have a significant influence on progression toward osteoarthritis, and patients with an intact supraspinatus show superior abduction and flexion strength. However, in cases where complete repair may not be possible and/or cost limitations may prohibit augmentation, partial repair can provide a respectable outcome.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!