Study Design: Finite element analysis.

Objective: To determine and compare the biomechanical stability of the bicortical short C2 pars screw fixation for high-riding vertebral artery (HRVA) with the C2 pedicle screw and C2 translaminar screw fixation in finite element models.

Summary Of Background Data: Fixation of C2 is technically demanding in the case of HRVA. However, there is no consensus on the alternative technique for the C2 screw fixation for HRVA in the literature.

Methods: A finite element model of the upper cervical spine (C0-C2) with HRVA had been developed. C1 pedicle screw was applied at C1 by using notching technique. Bicortical short C2 pars screws, C2 pedicle screws, and C2 translaminar screws were used in each model. Then a vertical load of 50 N and a 1.5 Nm torque were applied to the C0 to simulate flexion, extension, lateral bending, and axial rotation respectively.

Results: Compared with C2 pedicle screw fixation, the bicortical short C2 pars screw fixation increased the range of motion by -1.45%, 2.13%, 62.0%, and 22.0% under flexion, extension, lateral bending, and axial rotation, respectively. However, the C2 translaminar screw fixation increased the range of motion by 43.6%, 17.8%, 423.4%, and 19.9%, respectively. In terms of the peak von Mises stress, compared with C2 pedicle screw fixation, bicortical short C2 pars screw decreased 46.1%, 41.6%, 71.3%, and -12.5% under flexion, extension, lateral bending, and axial rotation, respectively; C2 translaminar screw decreased -2.66%, -4.87%, 73.0%, and -10.1%, respectively.

Conclusion: For a patient with HRVA, bicortical short C2 pars screw fixation provides sufficient stability and exhibited a smaller von Mises distribution on the screw-rod construct, indicating it could be an effective C2 internal fixation method for HRVA to promote C1-C2 stability and avoid the vertebral artery injury.Level of Evidence: N/A.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0000000000004141DOI Listing

Publication Analysis

Top Keywords

screw fixation
36
bicortical short
24
short pars
24
pars screw
20
finite element
16
pedicle screw
16
screw
13
vertebral artery
12
translaminar screw
12
flexion extension
12

Similar Publications

Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.

View Article and Find Full Text PDF

Outcomes of surgically treated posterior pelvic fractures in an Australian population: A multicenter study.

Injury

January 2025

Department of Surgery, The Trauma and Orthopaedic Research Unit, The Canberra Hospital, Garran, Australian Capital Territory, Australia.

Background: Unstable posterior pelvic-ring fractures are rare and difficult to manage. There are many injury patterns, they are associated with high morbidity and mortality, and optimal surgical management remains contentions. This study aims to compare outcomes and complications for different surgical management of these injuries.

View Article and Find Full Text PDF

Determinants for successful medullary fixation of the superior ramus.

Injury

January 2025

Department of Orthopaedic Surgery, Cedars - Sinai Medical Center, Los Angeles, CA, USA. Electronic address:

Objectives: The purpose of this study is to determine what demographic and anatomical variables affect successful placement of a superior medullary ramus screw, and how they affect the maximal diameter of that screw.

Methods: Design: Prognostic Level IV SETTING: Level I Trauma Center Patients/Participants: Two hundred consecutive patients underwent computed tomography (CT) of the pelvis. We included those patients aged 18 and older without osseous injury or abnormalities precluding measurement.

View Article and Find Full Text PDF

Preserving Cervical Mobility: A Novel Robot-Assisted Approach for Atlas Fracture Fixation.

Am J Case Rep

January 2025

Department of Orthopedic Surgery, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.

BACKGROUND The management of unstable atlas fractures remains a subject of ongoing debate and controversy. The conservative surgical treatment commonly involves fusion, resulting in severe loss of cervical spine mobility, and a large incisions and extensive tissue dissection are required. We aim to introduce a novel concept and surgical approach for treating atlas fracture, one that involves minimizing trauma while maintaining mobility of the upper cervical spine without resorting to fusion.

View Article and Find Full Text PDF

Unlabelled: Mandibular reconstruction is essential for restoring both function and aesthetics after segmental resection due to tumoral pathology. This study aimed to conduct a comparative analysis of three reconstruction strategies for defects resulting from segmental mandibular resection, utilizing finite element analysis (FEA).

Methods: A digital model of the mandible was created from CBCT data and optimized for FEA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!