High-resolution time-of-flight PET detector with 100 ps coincidence time resolution using a side-coupled phoswich configuration.

Phys Med Biol

Department of Radiology, Molecular Imaging Program at Stanford, School of Medicine, Stanford University, CA, United States of America.

Published: June 2021

Photon time-of-flight (TOF) capability in positron emission tomography (PET) enables reconstructed image signal-to-noise ratio (SNR) improvement. With the coincidence time resolution (CTR) of 100 picosecond (ps), a five-fold SNR improvement can be achieved with a 40 cm diameter imaging subject, relative to a system without TOF capability. This 100 ps CTR can be achieved for adetector design (crystal element length ≥20 mm with reasonably high crystal packing fraction) using a side-readout PET detector configuration that enables 511 keV photon interaction depth-independent light collection efficiency and lower variance in scintillation photon transit time to the silicon photomultiplier (SiPM). In this study, we propose a new concept of TOF-PET detector to achieve high (<2 mm) resolution, using a 'side-coupled phoswich' configuration, where two crystals with different decay times () are coupled in a side-readout configuration to a common row of photosensors. The proposed design was validated and optimized with GATE Monte Carlo simulation studies to determine an efficient detector design. Based on the simulation results, a proof-of-concept side-coupled phoswich detector design was developed comprising two LSO crystals with the size of 1.9 × 1.9 × 10 mmwith decay times of 34.39 and 43.07 ns, respectively. The phoswich crystals were side-coupled to the same three 4 × 4 mmSiPMs and detector performances were evaluated. As a result of the experimental evaluation, the side-coupled phoswich configuration achieved CTR of 107 ± 3 ps, energy resolution of 10.5% ± 1.21% at 511 keV and >95% accuracy in identifying interactions in the two adjacent 1.9 × 1.9 × 10 mmcrystal elements using the time-over-threshold technique. Based on our results, we can achieve excellent spatial and energy resolution in addition to ∼100 ps CTR with this novel detector design.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ac01b5DOI Listing

Publication Analysis

Top Keywords

pet detector
8
coincidence time
8
time resolution
8
tof capability
8
snr improvement
8
high-resolution time-of-flight
4
time-of-flight pet
4
detector
4
detector 100
4
100 coincidence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!