US homeland security concerns related to potential misuse of γ-ray-emitting radiation sources employed in radiobiological research (eg, shielded cesium-137 irradiators) led to recommendations by the National Research Council to conduct studies into possibly replacing γ-ray irradiators used in research involving small rodent and other models with X-ray instruments. A limiting factor is suitability of the X-ray photon energy spectra. The objective of our research was to demonstrate the suitability of the radiation energy spectrum of 320-kV X rays after filtration (HVL = 4 mm Cu) for in-vivo cytotoxicity studies in immunodeficient C.B-17 SCID mice. By using a previously-published Hazard Function (HF) model to characterize dose-response relationships for in vivo bone marrow and spleen cell survival fractions and also to characterize the acute lethality risk (hematopoietic syndrome mode) we demonstrate that the filtered 320-kV X-ray beam appears suitable for such studies. A key finding for C.B-17 SCID mice when compared to results previously obtained for immunocompetent C.B-17 mice is that the immunodeficient mice appear to be more radioresistant, implicating a possible role of the immune system capacity in radiosensitivity of mammals.