Selectivity limits of and opportunities for ion pair chromatographic separation of oligonucleotides.

J Chromatogr A

Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden. Electronic address:

Published: August 2021

Here it was investigated how oligonucleotide retention and selectivity factors are affected by electrostatic and non-electrostatic interactions in ion pair chromatography. A framework was derived describing how selectivity depends on the electrostatic potential generated by the ion-pair reagent concentration, co-solvent volume fraction, charge difference between the analytes, and temperature. Isocratic experiments verified that, in separation problems concerning oligonucleotides of different charges, selectivity increases with increasing surface potential and analyte charge difference and with decreasing co-solvent volume fraction and temperature. For analytes of the same charge, for example, diastereomers of phosphorothioated oligonucleotides, selectivity can be increased by decreasing the co-solvent volume fraction or the temperature and has only a minor dependency on the ion-pairing reagent concentration. An important observation is that oligonucleotide retention is driven predominantly by electrostatic interaction generated by the adsorption of the ion-pairing reagent. We therefore compared classical gradient elution in which the co-solvent volume fraction increases over time versus gradient elution with a constant co-solvent volume fraction but with decreasing ion-pair reagent concentration over time. Both modes decrease the electrostatic potential. Oligonucleotide selectivity was found to increase with decreasing ion-pairing reagent concentration. The two elution modes were finally applied to two different model antisense oligonucleotide separation problems, and it was shown that the ion-pair reagent gradient increases the selectivity of non-charge-based separation problems while maintaining charge-difference-based selectivity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2021.462269DOI Listing

Publication Analysis

Top Keywords

co-solvent volume
20
volume fraction
20
reagent concentration
16
ion-pair reagent
12
separation problems
12
ion-pairing reagent
12
selectivity
8
ion pair
8
oligonucleotide retention
8
electrostatic potential
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!