[Doppler echocardiography in assessing mechanical and biological heart valve prostheses].

G Ital Cardiol

Servizio di Poligrafia, Ospedale S. Camillo, Roma.

Published: February 1988

The study was performed to assess Doppler echocardiographic features of mitral and aortic prosthetic valves of different types with both normal and abnormal function. Two hundred and twenty-three patients with 250 prostheses were studied. Two hundred eight valves (111 mitral, 95 aortic and 2 tricuspid) were considered to be functioning normally after clinical examination, phonocardiography and M-mode and 2D echocardiography. This group enabled us to define normal Doppler echocardiographic findings for different types of prosthesis. In mitral position, peak (p) and mean (m) gradients were lower for disc prostheses and higher for ball and biological prosthetic valves; values of effective orifice area (A), calculated by pressure half-time method, were lower for biological and ball prostheses and higher in disc valves. Results were as follows: St. Jude (p 10.6 mmHg, m 3.9 mmHg, A 2.7 cm2), Duromedics (p 10.6, m 4.3, A 2.8), Björk-Shiley (p 10.4, m 4, A 2.3), Omniscience (p 14.2, m 6.2, A 2.1), Starr-Edwards (p 15.9, m 5.4, A 2.1), Hancock (p 14.7, m 6, A 2), Carpentier (p 13.2, m 5.4, A 1.9). Mild regurgitation, considered "physiological", was found in 2/8 Carpentier valves and in 3/34 St. Jude prostheses. In aortic valves lower peak gradients were found in Lillehei (18.3 mmHg), St. Jude (23.8 mmHg), Björk-Shiley (26 mmHg), Duromedics (27 mmHg) and higher values in Starr-Edwards (30.2 mmHg), Hancock (30 mmHg) and Omniscience (35.5 mmHg) prostheses. Mild regurgitation, considered "physiological", was found in 17% of Omniscience valves, 21% of Hancock, 33% of Duromedics, 45% of St. Jude, 60% of Björk-Shiley prostheses. Hancock mitral valves implanted for over 7 years had a mean gradient higher than valves with a shorter period of implantation (7.6 vs 4.85 mmHg, p less than 0.1), whereas the effective orifice area was similar. Hancock aortic valves implanted for over 7 years had a peak gradient slightly higher than the other group (implantation less than 7 years previously), but the difference was not statistically significant. Forty-two valves (19 aortic and 23 mitral) were considered to be malfunctioning. Regurgitation Doppler signals of malfunctioning valves appeared different from those of "physiological" reverse flow; in the former cases forward gradient was higher than normal prostheses. In stenotic aortic prostheses, peak systolic gradient was greatly increased; in stenotic mitral prostheses, a very significant increase in mean gradient and a great decrease in effective orifice area were found. In 14 patients who underwent surgical re-operation and in the patient who died before operation, Doppler echocardiographic findings were confirmed.(ABSTRACT TRUNCATED AT 400 WORDS)

Download full-text PDF

Source

Publication Analysis

Top Keywords

doppler echocardiographic
12
valves
12
effective orifice
12
orifice area
12
gradient higher
12
mmhg
10
prostheses
9
mitral aortic
8
prosthetic valves
8
echocardiographic findings
8

Similar Publications

Swine are increasingly utilized in cardiovascular research due to their anatomical and physiological similarities to humans, particularly for studying diastolic dysfunction. While MRI offers excellent structural imaging, echocardiography provides superior real-time assessment of diastolic parameters. To address the lack of standardized methods and reduce variability across studies, we present a comprehensive guide for performing echocardiography in Yorkshire pigs, detailing anatomical considerations, equipment requirements, and technical approaches.

View Article and Find Full Text PDF

Background: This study aimed to assess the accuracy of tricuspid spectral Doppler (E/A) and tissue Doppler parameters (E/E') to diagnose right ventricular diastolic dysfunction (RVDD) in comparison to American Society of Echocardiography (ASE criteria) in pediatric tetralogy of Fallot (TOF) patients after surgical repair.

Methods: This prospective, observational study was done at a tertiary care hospital involving 40 pediatric TOF patients aged less than 2 years who underwent complete intracardiac repair with cardiopulmonary bypass (CPB). Echocardiographic observations were made using a pediatric transesophageal echocardiography probe after surgical repair in the post-CPB period.

View Article and Find Full Text PDF

Association with Outcome of the Regurgitant-Volume Adjusted Right Ventricular Ejection Fraction in Secondary Tricuspid Regurgitation.

J Am Soc Echocardiogr

January 2025

Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy; Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Background: In patients with secondary tricuspid regurgitation (STR), right ventricular ejection fraction (RVEF) may not accurately reflect the actual RV systolic performance since a considerable amount of the RV stroke volume (SV) is regurgitated back into the right atrium. To overcome this limitation, we explored the association with the outcome of the effective RVEF (eRVEF), which accounts for the tricuspid regurgitant volume (RegVol).

Methods: 513 patients with STR (mean age 75±13 years, 39% atrial STR, 58% severe) underwent complete two-, three-dimensional, and Doppler echocardiography.

View Article and Find Full Text PDF

Total anomalous pulmonary venous return (TAPVR) is a high risk and rare cardiac malformation with a low prenatal detection rate and predicting obstruction in these cases is difficult. We sought to investigate fetal echocardiographic parameters associated with postnatal pulmonary venous obstruction (PPVO). We performed a retrospective review of 26 patients with TAPVR who had a fetal echocardiogram from 2010 to 2021.

View Article and Find Full Text PDF

Introduction We aimed to assess whether partial hepatectomy has an influence on conventional and speckle tracking parameters on echocardiography in living liver donors in the early postoperative period. Methods This study was a retrospective study to investigate the cardiac effects of liver donation after the transplant operation in a high-volume liver transplant center. Ninety living liver donors were included in the study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!