Corneal biomechanical parameters were compared in 100 keratoconus eyes with abnormal elevation on the back corneal surface only (group 1), versus both the back and front surfaces (group 2). Scheimpflug tomography with Pentacam HR, corneal biomechanical assessments using Corvis ST and Ocular Response Analyzer (ORA) and corneal epithelium thickness maps using anterior segment optical coherence tomography were assessed. There were no significant differences in the IOP measured using Corvis ST and ORA, age or sex between the two groups. Statistically significant differences were found in all corneal shape parameters and all new parameters of Corvis ST: corneal stiffness parameter at first applanation (SP-A1), integrated inverse radius (IR) and deformation amplitude ratio (DAR)) between groups (p < 0.001). The classic parameters of ORA including corneal hysteresis (CH) and corneal resistance factor (CRF) were about 1.00 mmHg higher in group 1 (p < 0.001). In conclusion, keratoconus eyes with abnormal elevation limited to the back corneal surface have lower grade, stiffer corneal biomechanical parameters and less asymmetric shape. This is consistent with progressive biomechanical weakening from the first detectable back surface elevation to manifestation on the front surface as the severity overwhelms the ability of the epithelium to compensate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8184812PMC
http://dx.doi.org/10.1038/s41598-021-91263-7DOI Listing

Publication Analysis

Top Keywords

corneal biomechanical
12
biomechanical parameters
8
keratoconus eyes
8
eyes abnormal
8
abnormal elevation
8
versus front
8
front surfaces
8
corneal
7
parameters
4
parameters keratoconus
4

Similar Publications

Inducing cylindrical and spherical defocus after implantation with new generation intraocular lenses improves intermediate and near visual acuity.

Sci Rep

December 2024

Imaging, Biomechanics and Mathematical Modelling Solutions Lab, Narayana Nethralaya Foundation, Bangalore, India.

An induced cylinder and spherical power after implantation with an extended depth of focus (EDOF) and enhanced monofocal intraocular lens (IOL) could improve distance, intermediate (60 cm) and near (40 cm) visual acuity (VA). In this prospective study, forty eyes with Eyhance EDOF IOL (Johnson and Johnson, USA) and 40 eyes with Vivity EDOF IOL (Alcon Laboratories Inc. USA) were included.

View Article and Find Full Text PDF

Evidence for spinal disinhibition as a pain-generating mechanism in fibromyalgia syndrome.

Pain Rep

February 2025

Pain Research Institute, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, United Kingdom.

Introduction: Pain phenomenology in patients with fibromyalgia syndrome (FMS) shows considerable overlap with neuropathic pain. Altered neural processing leading to symptoms of neuropathic pain can occur at the level of the spinal cord, and 1 potential mechanism is spinal disinhibition. A biomarker of spinal disinhibition is impaired H-reflex rate-dependent depression (HRDD).

View Article and Find Full Text PDF

Analyzing the effect of surgical and corneal parameters on the postoperative refractive outcomes of SMILE in myopic eyes based on machine learning.

Am J Ophthalmol

December 2024

Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China; School of Medicine, Nankai University, Tianjin, China; Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Ophthalmology Hospital, Tianjin, China; Nankai Eye Institute, Nankai University, Tianjin, China. Electronic address:

Purpose: To analyze the effect of individual parameters on the postoperative refractive outcomes of small incision lenticule extraction in myopic eyes using machine learning methods.

Design: Retrospective Clinical Cohort Study METHODS: We included 477 patients (922 eyes) of small incision lenticule extraction at Tianjin Ophthalmology Hospital and divided the patients into two groups to analyzed the factors affecting postoperative refractive outcomes based on the label of postoperative spherical equivalent (SE) ≤ -0.50D.

View Article and Find Full Text PDF

Expression of Yes-associated protein in endothelial cells of human corneas before and after storage in organ culture.

Sci Rep

December 2024

Laboratory of Biology, Engineering, and Imaging for Ophthalmology, BiiO, Faculty of Medicine, University of Jean Monnet, 10 rue de la Marandière, 42270, Saint-Priest en Jarez, France.

The cornea, the anterior meniscus-shaped transparent and refractive structure of the eyeball, is the first mechanical barrier of the eye. Its functionality heavily relies on the health of its endothelium, its most posterior layer. The treatment of corneal endothelial cells (CECs) deficiency is allogeneic corneal graft using stored donor corneas.

View Article and Find Full Text PDF

Cornea tissue engineering is strictly dependent on the development of biomaterials that fulfill the strict biocompatibility, biomechanical, and optical requirements of this organ. In this work, we generated novel biomaterials from the squid gladius (SG), and their application in cornea tissue engineering was evaluated. Results revealed that the native SG (N-SG) was biocompatible in laboratory animals, although a local inflammatory reaction was driven by the material.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!