In this study, a polyurethane vascular graft with excellent strength and compliance for clinical application was designed and fabricated by preparing three small-diameter vascular graft layers via the textile techniques of wet spinning and knitting. The polyurethane filament that was fabricated by wet spinning formed the inner layer. The polyurethane tubular fabric was used as the middle layer. The outer layer was prepared by spraying polyurethane solution. The three layers of the polyurethane vascular graft have uniform wall thickness, high strength, excellent compliance, and good puncture resistance compared with clinical poly(ethylene terephthalate) (PET) and expanded polytetrafluoroethylene (ePTFE) vascular graft. Therefore, these layers can have potential clinical applications in the replacement of the conventional artificial vascular graft prepared from PET and ePTFE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmbbm.2021.104614 | DOI Listing |
BMJ Open
January 2025
Bio Heart Cardiovascular Diseases Research Group, Bellvitge Institute for Biomedical Research, L'Hospitalet de Llobregat, Barcelona, Spain.
Introduction: Chronic hand ischaemia may affect some haemodialysis patients with an arteriovenous fistula (AVF) or graft (AVG), a condition known as haemodialysis access-induced distal ischaemia (HAIDI). Duplex ultrasonography (DUS) can provide comprehensive insights into anatomical and perfusion properties, and measuring the hand acceleration time (HAT) has been demonstrated to be sensitive within the framework of chronic upper limb ischaemia.
Methods And Analysis: This single-centre, prospective cohort study will involve adult end-stage renal disease (ESRD) patients requiring either AVF or AVG for haemodialysis.
Cell Stem Cell
January 2025
Department of Chemical and Biological Engineering, University of Wisconsin-Madison, Madison, WI, USA. Electronic address:
Tissue-engineered vascular conduits (TEVCs) are a promising blood vessel replacement. In a recent publication in Cell Stem Cell, Park et al. developed TEVCs comprised of decellularized human umbilical arteries lined with shear-trained, human induced pluripotent stem cell (hiPSC)-derived endothelial cells (ECs) that resisted thrombosis and exhibited patency upon grafting into the rat inferior vena cava (IVC).
View Article and Find Full Text PDFA A Pract
January 2025
From the Department of Anesthesia, Indiana University School of Medicine, Indianapolis, Indiana.
Interscalene blocks, commonly used for shoulder surgery analgesia, often cause transient phrenic nerve palsy, leading to hemi-diaphragmatic paresis. This complication is particularly problematic in patients with pulmonary comorbidities and has been extensively investigated. However, its impact on patients with Fontan physiology remains less understood with limited representation in the literature.
View Article and Find Full Text PDFFront Surg
December 2024
School of Medicine, Kyungpook National University, Daegu, Republic of Korea.
Background: Current guidelines recommend preserving at least one of the bilateral pelvic flows in patients with aortoiliac aneurysms. The sandwich parallel graft, using commercially available devices, provides a viable option for patients who fall outside the instructions for use of iliac branch devices. However, gutter endoleak remains a significant challenge.
View Article and Find Full Text PDFCureus
December 2024
Cardiovascular Surgery, Sapporo Medical University, Sapporo, JPN.
An a (AEF) is a rare but life-threatening condition where an abnormal connection forms between the aorta and the gastrointestinal tract, most commonly the duodenum. It can be primary (arising spontaneously due to an aortic aneurysm or infection) or secondary (complicating prior vascular surgery). Immediate recognition and surgical intervention are critical to manage severe gastrointestinal bleeding and prevent fatal outcomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!