Background: Implantation of left-ventricular assist systems (LVASs) has become the standard of care for advanced heart failure (HF). The absence of pulsatility in previous devices contributes to vascular and endothelial dysfunction related to atherosclerotic or vascular complications. We hypothesized that the artificial pulsatility provided by the HeartMate 3 (HM3) (Abbott, Chicago, IL) LVAS would exert a favourable effect on the vasculature.

Methods: In 32 patients implanted with HM3 (5 female patients, mean age 55 ± 13.6 years), the reactive hyperemia index (RHI) and peripheral augmentation index (AI), markers of endothelial function and arterial stiffness, were measured with an EndoPAT2000 before and in the third and sixth month after implantation. RHI and AI data from 30 HeartMate II (HM II) (Abbott) recipients in the third and sixth month after implantation, from 15 patients with advanced HF without LVASs and from 13 healthy volunteers were also analyzed.

Results: In HM3 recipients, the mean RHI significantly decreased at 3 and 6 months after implantation. The RHI was substantially lower at baseline than that of healthy or the HF reference group. Increasing AI values, indicating worsening arterial stiffness, were also observed. Similar trends were observed in HM II recipients between the third and sixth months but with higher absolute values of RHI and AI.

Conclusions: We detected impaired vascular function in HM3 patients and provided additional evidence on the negative effect of low pulsatility on vascular function after LVAS implantation. The results suggest that the artificial pulsatility of the HM3 does not avert the progression of endothelial dysfunction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2021.05.013DOI Listing

Publication Analysis

Top Keywords

artificial pulsatility
12
third sixth
12
endothelial dysfunction
8
arterial stiffness
8
sixth month
8
month implantation
8
implantation rhi
8
recipients third
8
vascular function
8
patients
5

Similar Publications

Dynamic EIT technology for real-time non-invasive monitoring of acute pulmonary embolism: a porcine model experiment.

Respir Res

January 2025

Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi'an, 710032, China.

Background: Acute pulmonary embolism represents the third most prevalent cardiovascular pathology, following coronary heart disease and hypertension. Its untreated mortality rate is as high as 20-30%, which represents a significant threat to patient survival. In view of the current lack of real-time monitoring techniques for acute pulmonary embolism, this study primarily investigates the potential of the pulsatility electrical impedance tomography (EIT) technique for the detection and real-time monitoring of acute pulmonary embolism through the collection and imaging of the pulsatile signal of pulmonary blood flow.

View Article and Find Full Text PDF

Background: Abdominal aortic aneurysm (AAA) is a localized bulge of the abdominal aorta, which mainly manifests as a pulsatile mass in the abdomen. Once an abdominal aortic aneurysm ruptures, the patient's life is seriously endangered. Surgery is the preferred treatment for abdominal aortic aneurysm.

View Article and Find Full Text PDF

Ruptured iliac artery aneurysms are serious conditions with high mortality, occasionally perforating into the venous system. A 73-year-old male presented with left leg edema and a pulsatile left lower abdominal mass. Computed tomography revealed a ruptured left common iliac artery aneurysm with perforation into the left common iliac vein.

View Article and Find Full Text PDF

Superovulation treatment leads to characteristic changes in uterine perfusion during the first three weeks of pregnancy in cattle, but the origin of these changes is unknown. We investigated embryo-induced effects on uterine blood flow volume (uBFV) and pulsatility index (uPI), as well as on steroid hormone concentrations during the first seven days after conception, together with endometrial gene expression at the time of embryo flushing, in Holstein Friesian cows. Animals (n = 8) underwent (a) artificial insemination (AI), (b) superovulation followed by artificial insemination (SOV-AI), and (c) superovulation followed by sham AI (SOV-control) in a Latin square design.

View Article and Find Full Text PDF

Background: Chronic venous insufficiency (CVI) is a common disease with a high prevalence. Incompetent venous valves are considered as one of the main causes. Besides compression therapy, various surgical therapies are practiced, whereby the reconstruction of valves is of central importance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!